![AGA ELLESMERE 4K Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/aga/ellesmere-4k/ellesmere-4k_installation-and-operating-instructions-manual_2865832019.webp)
18
TROUBLE SHOOTING
SYMPTOM
POSSIBLE CAUSES
REMEDY
Stove Difficult To Light
Air controls set incorrectly
Air controls must be set to maximum
settings on initial light-up
Moisture content of fuel too high
Ensure fuel is sufficiently dry
Fire Burns Too Quickly
Air controls set incorrectly
Adjust Air controls
Rope seals perished/worn
Replace rope seals
Excessive Chimney Draught
Seek professional chimney advice
Fire Burns Too Slowly/Low Heat
Output To The Room
Air controls set incorrectly
Adjust Air controls
Insufficient flue draught
Seek professional chimney advice
Ash buildup
Do not allow ashpan to overfill
Fire Bricks Cracked
Normal wear and tear
Replace firebricks when they begin to
crumble as apposed to showing minor
cracks
Grate Cracked
Build up of ash causing overheating
Replace the grate and do not allow ash-
pan to overfill
Operation with the ash door open
While the stove is in operation the door
should be closed
Burning non approved fuel
Burn correct fuel
Glass Sooting Up
Air wash not working
Open the air wash control
Moisture content of fuel too high
Ensure fuel is sufficiently dry
Insufficient flue draught
Seek professional chimney advice
Air controls set to minimum settings
Operate the stove at or close to the
nominal output
Smoking On Refuelling
Air controls set incorrectly
Air controls should be fully open prior to
refuelling
Insufficient flue draught
Seek professional chimney advice
Chimney or flueways in stove have
become partially blocked
Clean the flueways in the stove. If prob-
lem persists have the chimney cleaned
by a suitable competent person
Lack of combustion air
Ensure adequate sized air vent / air
supply to the room
Top baffle fitted incorrectly
Consult instructions to ensure baffle fitted
in correct orientation