AGA ELLESMERE 4K Скачать руководство пользователя страница 13

12

5.

Never allow a build up of ashes in the ash pan, 
as this may cause the grate to burn out prema-
turely.

6.

Allow adequate air ventilation to ensure plenty
of air for combustion.

7.

Do not burn rubbish/house hold plastic.  Do not
burn manufactured timber which contains glue.
Do not burn processed or pressure treated 
timber as this will create a very intense fire over
a short period of time which will damage the

appliance.

8.

Clean the chimney at least twice a year.

9.

Burning at a low burn rate or unseasoned timber
will stain the glass. Regular cleaning will prevent
permanent staining.

10. Keep all combustible materials a safe distance 

away from the appliance, please see section for
clearances to combustion.

11. For safety reasons never leave children, elderly

or infirmed unaccompanied while stove is in use.
Use a fireguard for solid fuel appliances in 
accordance with BS 8423:2002.

12. Avoid contact with appliance when in use as the

stove reaches very high operating tempera-
tures.

13. This appliance should be regularly maintained  

by a competent service engineer. Use only 
replacement parts recommended by AGA.  
Using unauthorised parts will invalidate
your guarantee and may cause damage or 
injury.

14. Do not use an aerosol spray on or near the 

stove when it is alight.

AN ODOUR WILL EMIT FROM STOVE ON FIRST
FIRING, WHEN FIRE REACHES MAXIMUM
TEMPERATURE OVER A NUMBER OF HOURS
THIS ODOUR WILL SUBSIDE.

IT IS BEST ADVISED TO OPEN WINDOWS 
DURING THIS PERIOD.

THIS ODOUR IS UNPLEASANT BUT NOT TOXIC.
YOU MAY WISH TO VACATE THE ROOM WHILE
THE PAINT CURES.

WARNING:  THE AIR CONTROLS/DOOR HAN-
DLE WILL BECOME HOT WHEN THE STOVE
HAS BEEN IN OPERATION FOR SOME TIME,
USE THE GLOVE/TOOLS PROVIDED WHEN
REFUELLING OR ADJUSTING AIR CONTROLS.

LIGHTING

Before lighting the stove check with the installer
that the installation work and commissioning
checks described in the installation instructions
have been carried out correctly and that the
chimney has been swept clean, is sound and
free from any obstructions. As part of the stoves
commissioning and handover the installer
should demonstrate how to operate the stove
correctly.

WARNING:- The paint on the stove gets finally
cured when the stove is lit, during the first fire
the paint can soften, the doors of the stove
should be closed but not latched during the first
fire, otherwise the rope on the door can become
embedded in the paint during final curing.

IMPORTANT: The first few fires should be rela-
tively small to permit the refractory to set prop-
erly and to season the stove.

1. Before lighting the stove, ensure that any build-

up in the firebox has been removed and that the
ashpan has been emptied.

2. Adjust the air control to the central position and 

push in fully.

3. Lay some firelighters on the grate with two 

handfuls of kindling. The kindling must be cut into
thin lengths and laid across each other in layers 
to allow for a quick lightup. Ignite the firelighters 
and close the door.

4. When the firebed has fully ignited and is starting

to die back add 3 small logs, or a small quantity 
of smokeless fuel.

5. Approximately 2 minutes after adding the logs the

door can be closed, but air settings remain 
un-altered.

6. When the fire from the 3 logs is dying back a 

normal fuel load of approx 1.2kg is to be added to
the fire.  Leave the air controls unaltered for 5 
minutes to ensure the new fuel load is well alight
before moving the air controls to the desired 
settings.

FIRE SAFETY

To provide reasonable fire safety the following
should be given serious consideration:

1. The installation of smoke detectors.

2.  A conveniently located fire extinguisher to con-

tend with small fires resulting from burning 
embers.

Содержание ELLESMERE 4K

Страница 1: ...n aged or infirm persons should be supervised at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled When using the stove in situations where children aged and or infirm persons are present a fireguard must be used to prevent accidental contact with the stove The fireguard should be manufactured in accordance with BS 8423 ...

Страница 2: ...stibles 5 14 Stove Dimensions 7 15 Technical Data 8 16 Air Controls 9 17 Recommended Fuels 9 18 Riddling 10 19 Refuelling 10 Refuelling onto a low firebed 10 Fuel overloading 10 Operation with door left open 10 20 Dampers Air Controls left open 10 21 De Ashing 10 22 Disposal of Ash 10 23 Maintenance 11 24 Chimney Cleaning 11 25 Important Notes 11 26 Lighting 12 27 Fire Safety 12 28 CO Alarms 13 29...

Страница 3: ...r is installed by a Competent Person registered with a Government approved Competent Persons Scheme HETAS Ltd operate such a Scheme and a listing of their Registered Competent Persons can be found on their website at www hetas co uk The installation must be completed in accordance with current National and European Standards and Local Codes It should be noted that the requirements and these public...

Страница 4: ...he flexible flue liner The chimney flue should be designed to allow for cleaning of the stove use pipes with cleaning doors where necessary Avoid the use of 90 degree elbows use 2 x 45o bends instead Horizontal runs of flue pipe should be avoided where it is unavoidable the maximum permitted horizontal run is 150mm The chimney flue must have the necessary clearance distance from combustible materi...

Страница 5: ... for when determining the effective free area of any vent Air vents direct to the outside of the building should be located so that any air current produced will not pass through normally occupied areas of the room An air vent outside the building should not be locat ed less than the dimensions specified within the Building Regulations and B S 8303 Part 1 from any part of any flue terminal These a...

Страница 6: ...o should smoke or fumes be emitted from the stove The customer should be warned to use a fire guard to BS 8423 2002 in the presence of children aged and or infirm persons LOCATION There are several conditions to be considered in selecting a location for your stove A Allowances for proper clearances to combustibles of the stove and flue pipes B The product must be installed on a non combustible hea...

Страница 7: ...REDUCED CLEARANCE TO COMBUSTIBLES With Heatshield See Figs 4a 4b 4c Fig 4a Fig 4b Fig 4c 6 Side wall to stove 28 700mm Back wall to stove 28 700mm Corner 25 635mm Mantle clearance 25 635mm ...

Страница 8: ...7 STOVE DIMENSIONS Fig 5 Note Dimensions stated are in milimeters and may be subject to a slight variation 4kW 6kW 5kW ...

Страница 9: ...peration e g intensive burning high fuel consumption and can also lead to permanent damage to the stove ELLESMERE STOVES TECHNICAL DATA 4 kW 5kW 6kW FUEL WOOD ANCIT WOOD ANCIT WOOD ANCIT Nominal Output Room 4 5 3 8 5 2 5 0 5 9 6 4 Typical refuelling intervals to obtain nominal outputs Hour 75 1 75 1 75 1 Fuel Gas Mass Flow g s 3 3 2 7 4 3 9 4 3 9 Flue Gas Temp at Nominal Output oC 263 190 263 245 ...

Страница 10: ...re to provide a little primary to maintain the fire When burning coal the air control should always be to the right of centre On initial light up the lever should be pushed slightly to the right and pushed fully in providing under grate air fully while still pro viding some window wash air to maintain a clear viewing glass See Fig 6 To engage the operating tool onto the air control rotate the tool...

Страница 11: ... on the left side of the stove While keeping the tool pushed in rotate in a circular motion which will cause the individual grate castings to rise and fall dislodging the ash into the ashpan See Fig 9 Remember to reset the controls after refuelling DAMPERS AIR CONTROLS LEFT OPEN Operation with the air controls or appliance dampers open can cause excess smoke The appliance must not be operated with...

Страница 12: ...ick Lift the stainless steel baffle and catch a back brick on the top edge and tilt it forward to remove it Lift and hold the stainless steel baffle while catching the remaining back brick on the top edge and tilting it forward to remove it 11 WARNING NOTE Properly installed operated and maintained the stove will not emit fumes into the dwelling Occasional fumes from de ashing and re fuelling may ...

Страница 13: ...S LIGHTING Before lighting the stove check with the installer that the installation work and commissioning checks described in the installation instructions have been carried out correctly and that the chimney has been swept clean is sound and free from any obstructions As part of the stoves commissioning and handover the installer should demonstrate how to operate the stove correctly WARNING The ...

Страница 14: ...baffle on the right hand side while holding it up catch the top edge of the right hand side brick and lower it into the stove to allow for removal Remove the cast iron baffle cleaning door by lifting it forward while sliding it to the right clear of the left hand side brick this will allow the back edge be low ered so the baffle is almost vertical allowing it be manoeuvred through the door opening...

Страница 15: ...ve the broken glass c Clean the glass recess in the door d Place the glass into the door recess and replace the four corner clips e Tighten screws f Replace glass only with ceramic glass 5mm thick PROLONGED PERIODS OF NON USE If the stove is to be left unused for a prolonged peri od of time then it should be given a thorough clean to remove ash and unburned fuel residues To enable a good flow of a...

Страница 16: ... PLATE 177A_0000_161 14 HINGE PIN STOP 177A_0000_171 15 SHELL BRACKET 177A_0000_181 16 ASHPIT COVER 177A_0000_211 17 RIDDLING ROD RETAINER 177A_0000_221 18 STOVE SHELL 177A_0100_001 19 FIRE DOOR 177A_0300_011 20 HINGE LINK 177A_0300_021 21 DOOR LATCH 177A_0300_041 22 GLASS 177A_0300_051 23 GLASS CLIP 177A_0300_061 24 DOOR HANDLE 177A_0300_071 25 WASHER 177A_0300 _081 26 HOB 177A_0600_001 27 RIDDLI...

Страница 17: ... PLATE 177A_0000_161 14 HINGE PIN STOP 177A_0000_171 15 SHELL BRACKET 177A_0000_181 16 ASHPIT COVER 177A_0000_211 17 RIDDLING ROD RETAINER 177A_0000_221 18 STOVE SHELL 177B_0100_001 19 FIRE DOOR 177B_0300_011 20 HINGE LINK 177B_0300_021 21 DOOR LATCH 177A_0300_041 22 GLASS 177B_0300_051 23 GLASS CLIP 177A_0300_061 24 DOOR HANDLE 177A_0300_071 25 WASHER 177A_0300 _081 26 HOB 177B_0600_001 27 RIDDLI...

Страница 18: ... PLATE 177A_0000_161 14 HINGE PIN STOP 177A_0000_171 15 SHELL BRACKET 177A_0000_181 16 ASHPIT COVER 177A_0000_211 17 RIDDLING ROD RETAINER 177A_0000_221 18 STOVE SHELL 177A_0100_001 19 FIRE DOOR 177C_0300_011 20 HINGE LINK 177B_0300_021 21 DOOR LATCH 177A_0300_041 22 GLASS 177A_0300_051 23 GLASS CLIP 177A_0300_061 24 DOOR HANDLE 177A_0300_071 25 WASHER 177A_0300 _081 26 HOB 177C_0600_001 27 RIDDLI...

Страница 19: ...ating Replace the grate and do not allow ash pan to overfill Operation with the ash door open While the stove is in operation the door should be closed Burning non approved fuel Burn correct fuel Glass Sooting Up Air wash not working Open the air wash control Moisture content of fuel too high Ensure fuel is sufficiently dry Insufficient flue draught Seek professional chimney advice Air controls se...

Страница 20: ...nstallation Final cure of the painted surfaces This odour is unpleasant but not toxic It is best advised to ventilate the room and leave unoccupied Incorrect sealant used All flue Joints must be sealed with fire cement only Insufficient flue draught Seek professional chimney advice Water In Base Of Stove Condensation on light up It is acceptable to have a little condensa tion on start up when the ...

Отзывы: