Fault Finding
HIGH SMOKE NUMBERS
OIL SMELLS
INCORRECT
COMBUSTION
SETTINGS
RE-ADJUST
TO
INSTALLATION
INSTRUCTIONS
AIR INTAKE
BLOCKED
CHECK AIR
INLET TO
BURNER
NOZZLE FAULT
REPLACE
NOZZLE
OIL SOAKED
HEARTH
BURNER
FAULT
OIL LEAKS AT
PIPE FITTINGS
TAKE APART
AND
REMAKE AS
REQUIRED
LEAKS AT
TUBING
CONNECTORS
ENSURE END
OF TUBING
SQUARE
NUMEROUS
LOCK-OUTS
CURE THE
LOCK-OUT
CONDITION
ODOURS
IN
KITCHEN
OIL PRESSURE
INCORRECT
ADJUST TO
RECOMMENDED
SETTINGS
INCORRECT
COMPONENTS
USED ON
COMBUSTION
HEAD
SEE SERVICING
INSTRUCTIONS
INTERNAL
INSULATION
PANELS
INCORRECTLY
POSITIONED
OR
FAULTY
Содержание DESN 515906