15
1.234" (31.3 mm)
.991" (25.2 mm)
SECTION A-A
SCALE 1 : 1
LOCK
NUT
BRASS EXTENSION
CAM
PHILLIPS SCREW
13/16 COUNTER
BORE 7/16 DEEP
1/2 HOLE
3/4 INCH
WOOD PANEL
SPRING WASHER
INNER
DOOR
OVERLAY DOOR PANEL INSTALLATION
Figure 21
Figure 19
Step 5: Assemble lock parts
Two (2) lock extensions are provided with the lock. Use the
longer extension for
3
⁄
4
" thick overlay panels and the shorter
one for
5
⁄
8
" thick overlay panels. Assemble the lock exten-
sion, cam stop washer, spring washer, and set screw to the
lock as shown in Figure 20 and 21.
Install this lock assembly into the lock hole in the overlay
panel and secure with the retaining nut on the back side
with a 15 mm socket and ratchet. Make sure the key slot in
the front of the lock is vertical.
Step 6: Install lock cam
Attach the lock cam to the back of the lock assembly with
the phillips head screw provided. Orient the lock cam verti-
cally when installing on the lock.
3
1
⁄
2
"
(89 mm)
Counter bore
lock hole
on back side.
Figure 19a
#10 x
1
⁄
2
"
screw
1
⁄
2
" (13 mm) diameter drill
through door panel, from
other side (see detail
above)
13
⁄
16
" (20.5 mm)
counter bore,
7
⁄
16
" (11 mm)
deep.
17
⁄
32
"
(13.7 mm)
Figure 20
Hinge side of door