RECOMMENDED ROUGH IN OPENING DIMENSIONS, INDOOR MODEL 60RDE

DIMENSIONS INDOOR MODEL 60RDE

23-7/8”

(60.7 cm)

Anti tip Bracket must be 
installed for freestanding ap

-

plications. Can be removed for 
built in applications.

Front and Rear
Leveling Legs

1-7/8”

(4.8 cm)

24-1/4”

(61.6 cm

)

34-1/4” to 34-1/2”

(87 to 87.6 cm)

22”

(55.9 cm)

26-1/32”

(66.1 cm)

46”

(116.8 cm)

47-25/32”

(121.4 cm)

Drawer fully opened

Drawer fully opened

5

Electrical Requirements: 115 volts, 3.3 
amps running max. 15 amp dedicated 
circuit required. 3 prong grounded 
receptacle required.

Power outlet can be located in the back 
wall behind unit. Add 1” to depth for 
thickness of plug, or recess outlet 1” 
into the wall. Power outlet can also be 
installed in adjacent cabinetry with a 
cutout for routing of power cord. Follow 
all local building codes when installing 
electrical and unit.
Product weight = 170 lbs. (77.1 kg.)

*Depth dimension may very depending on each 
individual installation.

24”

(61 cm)

34-1/2”

(87.6 cm)

Alternate 
outlet location 
in adjacent 
cabinetry.

*24” (61 cm)

standard cabinet depth

Содержание 60RDE

Страница 1: ...Installation Operation and Maintenance Instructions Refrigerated Drawer Model 60RDE...

Страница 2: ...y Important Safety Instructions Warnings and safety instructions appearing in this guide are not meant to cover all possible conditions and situations that may occur Common sense caution and care must...

Страница 3: ...N DAMAGED MERCHANDISE TO THE MANUFAC TURER FILE THE CLAIM WITH THE RETAILER Help Prevent Tragedies Child entrapment and suffocation are not problems of the past Junked or abandoned refrigerators are s...

Страница 4: ...l Code and applicable local codes and ordinances see Figure 2 If the circuit does not have a grounding type re ceptacle it is the responsibility and obligation of the customer to exchange the existing...

Страница 5: ...evice 1 Push the unit against the wall so the anti tip bracket is flush to the wall adjacent to the back panel Level the unit with the leveling legs provided in the cabinet bottom See Leveling Legs on...

Страница 6: ...Requirements 115 volts 3 3 amps running max 15 amp dedicated circuit required 3 prong grounded receptacle required Power outlet can be located in the back wall behind unit Add 1 to depth for thickness...

Страница 7: ...ture variance at different locations within the cabinet Load Your Appliance Load your appliance with your desired items Please note that it may take up to 24 hours for your refrigerator to reach the d...

Страница 8: ...h red This will warn you that your contents have seen temperatures that may not be con ducive for long term storage This alarm can be reset by pressing the ON OFF button Power Failure If your unit exp...

Страница 9: ...key while pressing the F C key four 4 times in seven 7 seconds The display will flash SA seven 7 times then the unit will enter Sabbath Mode The display audible alarms LED and lights will be disabled...

Страница 10: ...ag nostics Mode will automatically exit after five 5 minutes of no keypad entry Display Error Code Reference The microprocessor in the control continually monitors critical refrigeration sys tem compo...

Страница 11: ...inet The painted cabinet can be washed with either a mild soap and water and thoroughly rinsed with clear water NEVER use abra sive scouring cleaners Interior Wash interior compartment with mild soap...

Страница 12: ...r optimum storage and organization of storage space P N 42245444 for 60RDE upper drawer P N 42245445 for 60RDE lower drawer For further information on available options visit the AGA MARVEL web site a...

Страница 13: ...ot go out when drawer is closed Drawer not activating light switch Unit not level level unit See page 3 leveling legs Noise or Vibration Unit not level Level unit see Leveling Legs on page 3 Unit will...

Страница 14: ...the service and support section In all correspondence regarding service be sure to give the model number serial number and proof of purchase Try to have information or description of nature of the pro...

Страница 15: ...l supply replacement parts for the hermetically sealed refrigeration system which consists of the compressor condenser drier accumulator bypass valve con necting tubing and the evaporator that are pro...

Страница 16: ...notice Such revisions do not entitle the buyer to corresponding changes improvements additions replacements or compensation for previously purchased products www agamarvel com P O Box 400 1260 E VanDe...

Отзывы: