RECOMMENDED ROUGH IN OPENING DIMENSIONS, MODEL 6ADAM
DIMENSIONS FOR MODEL 6ADAM
15
* Depth dimension may vary depending on
each individual installation.
Electrical Requirements: A grounded 115 volt, 15
amp dedicated circuit is required.
Power outlet can be located in the back wall
behind unit. Add 1" to depth for thickness of plug,
or recess outlet 1" into the wall. Power outlet
can also be installed in adjacent cabinetry with a
cutout for routing of power cord. Follow all local
building codes when installing electrical and unit.
Product weight = 130 lbs. (59.1 kg.)
** Minimum rough in opening required is to be
larger than the adjusted height of the
cabinet.
*24" (61 cm)
standard cabinet
depth
24" (61 cm)
** 31
3
⁄
8
" to 32
3
⁄
8
"
(79.7 to 82.2cm)
23
7
⁄
8
"
(60.7 cm)
31
1
⁄
8
" to 32
1
⁄
8
"
(79.1 to 81.6 cm)
22"
(55.9 cm)
47"
(119.4 cm)
26"
(66.0 cm)
24
1
⁄
16
"
(61.1 cm)
25
11
⁄
16
"
(65.3 cm)
3" to 4"
7.6 to 10.2cm)
Door needs to be opened to
this dimension to remove and/
or adjust the shelving
20" (50.8cm)