S H O P O N L I N E @ W W W . A G S P R A Y . C O M
33
1
Hydraulic Control Assembly
for HM Series Motors
Form L-1575
Rev. A
Original Instruction Manual
KEEP FOR FUTURE REFERENCE
The Hypro hydraulic control assembly is designed to directly mount to modified Hypro HM series
hydraulic motors. The control assembly provides a convenient solution for increased efficiency and
damage prevention from abuse conditions.
Technical Details
Operating Pressure (max):
Inlet: 3000 PSI (207 bar) Outlet: 3000 PSI (207 bar)
Regulated Flow (max):
14 GPM (53 LPM) – Bypass Port Plugged (0 gpm Bypass)
15 GPM (57 LPM) - Bypass Port Open (15 gpm Max Bypass)
Electrical:
Voltage: 12 VDC
Frequency: 110 Hz
Valve Type: Normally Closed Proportional Flow Control
Threshold (Activation) Current: 350+/-100 mA
Max. Control Current: 1600+/-200 mA
Initial Current Draw: 2.7 amps
Power: 32.8 watts
Resistance: 4.5 ohms at 68 degree F (20 degree C)
Storage Temperature: 32 to 140 degrees F (0 to 60 degrees C)
Fluids: Mineral based or synthetic hydraulic fluid at viscosities of 7.4 to 420 cSt
OUT
IN
CV2
PV
BYPASS
CV1
M2
M1
1
Hydraulic Control Assembly
for HM Series Motors
Form L-1575
Rev. A
Original Instruction Manual
KEEP FOR FUTURE REFERENCE
The Hypro hydraulic control assembly is designed to directly mount to modified Hypro HM series
hydraulic motors. The control assembly provides a convenient solution for increased efficiency and
damage prevention from abuse conditions.
Technical Details
Operating Pressure (max):
Inlet: 3000 PSI (207 bar) Outlet: 3000 PSI (207 bar)
Regulated Flow (max):
14 GPM (53 LPM) – Bypass Port Plugged (0 gpm Bypass)
15 GPM (57 LPM) - Bypass Port Open (15 gpm Max Bypass)
Electrical:
Voltage: 12 VDC
Frequency: 110 Hz
Valve Type: Normally Closed Proportional Flow Control
Threshold (Activation) Current: 350+/-100 mA
Max. Control Current: 1600+/-200 mA
Initial Current Draw: 2.7 amps
Power: 32.8 watts
Resistance: 4.5 ohms at 68 degree F (20 degree C)
Storage Temperature: 32 to 140 degrees F (0 to 60 degrees C)
Fluids: Mineral based or synthetic hydraulic fluid at viscosities of 7.4 to 420 cSt
OUT
IN
CV2
PV
BYPASS
CV1
M2
M1