Function
No.(V)
Description
Reset Calibration
Pan Calibration
After entering the sub-interface, you can adjust the
motor such as X-axis and Y-axis.
Reset position to compensate for errors in hardware
installation.
Adjustment range -128~+127. +0 means no adjust
-
ment.
Tilt Calibration
Color Calibration
Gobo Calibration
Focus Calibration
Prism1 Calibration
Prism2 Calibration
Rainbow Calibration
Frost Calibration
Sensor Monitor
Pan Hall
0 when magnetic is detected, otherwise 1
Tilt Hall
Color Hall
Gobo Hall
Focus Hall
Prism1 Hall
Prism2 Hall
Panwheel State
2 digits, each corresponding to a photoelectric switch
in the encoder disc
Tiltwheel State
Panwheel Step
Towards the positive direction, the step value should
increase. Towards the negative direction, the step va
-
lue should be reduced. The value is the same every
time you go to a certain point
Tiltwheel Step
System Error
(See common mis
-
takes)
If the red ERR indicator is lit, the luminaire is running.
After viewing, you can press the "Clear" button to clear
the error record.
DMX Monitor
This enters the sub-interface and displays the channel
values.
Error
Description
MT board connection failed
The driver board did not respond. Serial communication line
connecting display panel and driver board
There is a problem, or there is a problem with the driver
board.
Pan Reset failed
X-axis photoelectric switch, or problem with X-axis motor
Tilt Reset failed
Y-axis photoelectric switch, or problem with Y-axis motor
Pan Hall failed
Pan Hall have problem
Tilt Hall failed
Tilt Hall have problem
Color Wheel Reset failed
Color Wheel Hall, or Color Wheel motor have problem
Gobo Wheel Reset failed
Gobo Wheel Hall, or Gobo Wheel motor have problem
Focus Reset failed
Focus Hall, or Focus motor have problem