- 4 -
Setting interface:
Press “MENU” to enter the Setting interface, press the “MENU” button to enter different options until you return to the main
interface.
Advanced menu:
Press “MENU” 3 seconds to enter the advanced setup interface, press MENU key to enter different options, press MENU during
3 seconds to return to the main interface.
USE:
Power cable connection:
For convenient use, there are power supply cables and power supply ex-cables. Power Supply ex-cable allows connecting up to 6
units in cascade. All power plugs are industrial plugs with lock, you need to toggle snap and rotate when using.
If you use mobile power plate, be sure to use good quality and match rated power products. 6 pcs machines requires around
2000 watts, cores should be over 1.5mm².
Wireless remote control mode:
If the remote control cannot work, please check whether wireless function was turn on.
Press MENU to switch to wireless control setting, menu is set to “ON”, press “ENTER”.
This interface can also be matching code with remote controller.
The unit can be controlled by both DMX and remote controller. If a DMX is applied, wireless remote controller will not work.
When using remote control you need to pull out the antenna.
Options
Range
Set DMX
Address
1-512
Set the DMX address. Machine become a wireless host and can send out DMX signal when its address
is “1++”.
Wireless Control ON/OFF Wireless function switch. you can match code When shows “ON”
Manual
Fountain
ON/OFF Manual fountain switch, for testing purposes only.
Auto Clear
Delay
0.1-0.9s Automatic cleaning of the pipes and nozzle.
Options
Range
Instructions
Set Temperature
500-610
Setup inner Core temperature.
Auto Heat
ON/OFF
Auto preheat function switch after turn on machine
Density
70-100
Adjust the sparks density.
Mode Selection
Factory Mode/User Mode
Factory Mode is factory debugging mode, User Mode is using mode
Tip Over Error
ON/OFF
Tilt function switch.
Default Parameter
Press “ENTER” to restore all parameters to the factory settings.