EN
6
© Copyright LOTRONIC 2022
STATUS ICONS
When the icons are green, the machine works normally. When they are yellow, the operation is
abnormal.
Blower Motor
Shaft motor
Hopper motor
Temp sensor unconnected
Temp overheat
Tip over
Lack of time
PCB too hot
Sub PCB connected
2/3 channel output
RDM FUNCTION
RDM allows a console with RDM function to define DMX address and starting temperature of
spark jet.
DMX OPERATION
Channel
DMX address
Function
CH1
0-10
Stop
11-255
Fountain height 1-25
CH2
0-200
Pre-heat off
11-39
Emergency stop
56-200
Clear material
240-255
Pre-heat on
CH3
0-255
Density adjustment (0 is maximum density)
Safety channel
0-200
Control off
201-255
Control On
INITIAL SETTING
Setting
Range
Default
Set temperature
400-620
560
DMX address
1-512
1
DMX channel mode
3/2
3
Density
30-100
100
Safety address
0-512
OFF (0)
Tilt sensor
ON/OFF
ON
Restore defaults
YES/NO
NO
TFT backlight
ON/OFF
ON
Auto heating
ON/OFF
ON
Turn on power.
Check the status icons. If the icons are yellow, operation is abnormal. Please ask a professional to
check and repair the machine.
The sparking temperature of the machine is the factory default temperature. The machine will