© Copyright LOTRONIC 2016 BEAM1R
Page 6
ON
Lamp light directly after power on, And must wait for the lamp light up
success then reset
Restore to default set
Press ok key see the confirmation dialog box, Press OK key to restore to
default set
2.3. Manual control interface
This interface use for control present light, And then auto enter into master mode (didn’t received DMX signal, sent
the dmx signal to slave light)
Manual menu will according to standard 12Channel to set menu(Dimmer and strobe no using)
Option
Instruction
1CH. X
0~255
Press OK key into edit state, Then selected hundreds place. Press up or down,
change address code. Press OK key again, selected ten place and edit. Press
OK key again, select the first place and edit. Press it to exit the edit state.
……
0~255
12CH.
Macro
function
0~255
13CH. Reset
Press ok key see the confirmation dialog box, Press OK key to reset surface, all
motors reset
2.4 System information
Option
Instruction
Software version
Current software version
DMX Channel
Enter into sub-surface, using value and percentage show the DMX channel to check
System error record
If the red ERR indicator light light on, it means fixture running error, and enter the
sub-surface to check the
details. Press “Clear” to empty the error record after finish check
Note: Sometimes it not the installation problem of Hall or optocoupler. It is because
the motor cable inversely connect
Total using hour
Total using hour (accurate to minute)
This time using hour
The using hour from the power on (accurate to minute)
Total lighting hour
Total lighting hour (accurate to minute)
This time lighting hour
This time lighting hour (accurate to minute)
Error information
Instruction
Reset fail, uart error
Driver board
doesn’t respond. There is problem in the uart communication line of
display board and driver board. Or the driver board problem.
Pan reset fail
X photoelectric switch, or X Motor problem
Tilt reset fail
Y photoelectric switch, or Y Motor problem
Pan Hall error
Problem in X Hall
Tilt Hall error
Problem in Y Hall
Motor Colour reset fail
There is problem in Color wheel hall, or Color wheel motor
Motor Gobo reset fail
There is problem in Gobo wheel hall, or Gobo wheel motor
Lamp control fail
Lamp light on or off fail, there is problem in ballast or lamp
lamp hours too long,
pls replace
The total lamp light hour over the Maximum lamp light hour in “high class” menu. Remind
the user change the lamp in time. And then clear the lamp light hour i
n “high class”, timer
reset