4.5.2
Submersible probe
* Accuracy of the complete system with reference to the indication of the liquid level in mm: ±1.5 % FSO,
IEC 60770.
Parameter
Value
General specifications
Dimensions (Ø x L)
24 x 64.5 mm
Weight
350 g
Cable length
6 m
Pressure range
0-400 mbar
Measuring accuracy*
< ± 0.5 %
Temperature error
< ± 0.3 % FSO, 10 K
in compensated range 0 ... 70 °C
Operating temperature range
Medium
-5 ... 70 °C
Storage
-5 ... 70 °C
Electrical safety
Degree of protection (EN 60529)
IP 68
Electromagnetic compatibility (EMC)