9
Product description
EN
DIT 10
4.5
Technical data
4.5.1
Control unit
* Accuracy of the complete system with reference to the indication of the liquid level in mm: ±1.5 % FSO,
IEC 60770.
Parameter
Value
General specifications
Dimensions (Ø x L)
75 x 50 mm
Cable length
5 m
Housing material
PA6 15 % glass-loaded
Display
Graphic, 4 digits
Measuring accuracy*
± 1.5 %
Function
Level measurement
Operating temperature range
Ambient
0 ... 45 °C
Medium
-5 ... 70 °C
Storage
-5 ... 80 °C
Electrical data
Degree of protection (EN 60529)
IP 51
Supply voltage
Nominal voltage
3.6 V
Electromagnetic compatibility (EMC)