13
Mounting
EN
Wireless smoke alarm ASD 20
5
Mounting
Mount the product to the ceiling, if possible in the middle of the room.
5.1
Preparing mounting
Ensure that the product is mounted with a distance of at least 50 cm from
the wall, a joist or from other objects.
If you intend to mount multiple products, start by creating a mounting plan
with the appropriate mounting locations. Then label the products with
numbers or the corresponding mounting location to help avoid confusion
of mounting locations.
Prior to mounting, verify that the solar-operated energy storage module of
the wireless mounting base ASD 20 has been charged.
- Regular daylight is sufficient for charging the energy storage module.
- Exposure to direct sunlight reduces the charging time.
Verify that the solar cell of the wireless mounting base ASD 20 is mounted
facing towards the light source.
5.2
Teaching in
Verify that the wireless mounting base ASD 20 is in the vicinity of the
AFRISOhome gateway.
Verify that the AFRISOhome gateway is in "Learn" mode. See the operat-
ing instructions of the AFRISOhome gateway for information detailed
information.
NOTICE
ELECTROSTATIC DISCHARGE
•
Always earth yourself before touching electronic components, for example,
the LRN key.
Failure to follow these instructions can result in equipment damage.
Содержание Cavius ASD 20
Страница 27: ...27 Anhang DE Funk Rauchwarnmelder ASD 20 14 2 EU Konformitätserklärung ...
Страница 28: ...28 Anhang DE Funk Rauchwarnmelder ASD 20 14 3 Testbericht CNPP ...
Страница 29: ...29 Anhang DE Funk Rauchwarnmelder ASD 20 14 4 CE Zertifikat ...
Страница 30: ...30 Anhang DE Funk Rauchwarnmelder ASD 20 ...
Страница 57: ...27 Appendix EN Wireless smoke alarm ASD 20 14 2 EU Declaration of Conformity ...
Страница 58: ...28 Appendix EN Wireless smoke alarm ASD 20 14 3 Test report CNPP ...
Страница 59: ...29 Appendix EN Wireless smoke alarm ASD 20 14 4 CE certificate ...
Страница 60: ...30 Appendix EN Wireless smoke alarm ASD 20 ...