Commissioning
6.1
Commissioning the product (adaptation)
The AFRISOhome gateway is required to operate the product.
After you have inserted the batteries, the actuator moves to the mounting
position.
1. Select a suitable adapter
(B) (figure shows Danfoss
RAV) and mount it to the
radiator valve (A).
2. Turn the actuator (D) onto
the adapter (C) by using a
union nut (figure shows
Danfoss RAV).
1. Press the adaptation button (A)
after you have mounted the prod-
uct.
- The actuator is adapted and
stops with closed valve.