![AFRISO AVD 10 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/afriso/avd-10/avd-10_operating-instructions-manual_2864788024.webp)
8
Mounting
EN
AVD 10
5.3
Mounting the product
The product can be mounted to the standard valve bodies. Since it is not nec-
essary to interrupt the heating water circuit, mounting does not lead to dirt or
water stains.
1. Completely remove the
grey plastic connections
(A) between the plastic
adapters before using one
of the enclosed adapters.
A. Radiator valve
B. Adapter (if required)
C. Actuator
Type
Figure
Heimeier, Junkers Gyr, MNG, Hon-
eywell, Braukmann thread M 30 x 1.5
No adapter required
Danfoss RAV (the enclosed pin must be
plugged onto the valve rod)
+ enclosed pin
(RAV only)
Danfoss RA
Danfoss RAVL
A
A
B
C