11
Mounting
EN
MS
1. Mount the discharge line with a gradient and according to the table below.
Length of the
discharge line
Number of
elbows
Minimum nominal diameter DN
Discharge open-
ing G3/4
Discharge open-
ing G1
≤
2 m
≤
2
20
25
≤
4 m
≤
3
25
32
2. Route the end of the discharge line into an outlet or a container that can
hold the total capacity of the system.
The discharge opening is designated
by an arrow on the valve body.
Fig. 2: Installation without discharge line (left)
Fig. 3: Installation with discharge line (right)