12
Mounting
EN
Unitop
5
Mounting
5.1
Mounting the product
Verify that the housing is accessible and easy to oversee at all times.
Verify that the housing is protected against water and splash water.
Verify that the housing is not mounted in a humid room.
Verify that the ambient temperature is not exceeded at the housing.
Verify that the housing is protected from direct sunlight.
1. Drill two holes at the same height at a distance of 13 cm.
- Use the enclosed drilling template.
2. Insert the enclosed dowels.
3. Screw in the screws up to approx. 1.5 cm.
4. Fit the product onto the screws and slightly pull it down.
- The lug is flush with the wall.
5. Fasten the product to the wall by means of the third screw.
5.2
Adjusting the measuring range and calibrating the zero point
The measuring range and the zero point must be accurately adjusted for the
product to operate with maximum measuring accuracy.
Verify that the measuring
line has not yet been con-
nected or open the vent
cap (A). The system must
be unpressurised.
A