Technical specifications
12 TankControl
01
Parameter
Value
Material
Housing Stainless
steel
1.4305
Cable
PVC fuel oil-resistant
Spacer POM,
PE
Other wetted parts
Ceramics, silicon, silicon glue, Viton
Operating temperature range
Medium
-25 °C to +70 °C
Storage
-25 °C to +70 °C
Electrical safety
Protection
IP 68 EN 60529
Electromagnetic compatibility (EMC)
Interference
According to EN 61000-6-4
Noise immunity
According to EN 61000-6-2
* Accuracy of the complete system relating to indication of the liquid
level in mm: < ±1.5 % FSO, IEC 60770
Screw connections at the control unit
Cable gland
Cable diameter
M16 4.0-8.8
mm
M20 8.0-12.5
mm
4.1 Approvals,
tests,
conformities
TankControl complies with the EMC Directive (89/336/EEU and
92/31/EEU) and the Low Voltage Directive (73/23/EEU and
93/68/EEU).