![Afriso EURO-INDEX RG 210 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/afriso-euro-index/rg-210/rg-210_instruction-manual_2864874019.webp)
Shutting down and disposal
RG 210
19
Problem
Possible reason
Remedy
Wrong operating
mode selected.
X
Check operating
mode.
Wiring defective.
X
Check wiring.
Probes inter-
changed.
X
Check probes.
Green LED and the
relay do not switch
as described in
chapter 3.1, page 7.
Control unit de-
fective.
X
Replace control unit.
Other malfunction.
–
X
Return the device to
the manufacturer.
10 Shutting down and disposal
1.
Disconnect mains supply.
2.
Remove the device (see chapter 6, page 13, reverse sequence
of steps).
3.
To protect the environment, this device must
not
be disposed of
together with the normal household waste. Dispose of the de-
vice according to the local conditions and directives.
This device consists of materials that can be reused by recycling
firms. The electronic inserts can be removed easily and are con-
structed from recyclable materials.
If you do not have the opportunity to dispose of the old device in ac-
cordance with environmental regulations, please contact us for pos-
sibilities to dispose of it or to return it.
11 Spare parts and accessories
Part Part
No.
Control unit
53206
PTC thermistor probes type 150
53208
PTC thermistor probes type 937
53204
Cable extension fitting KVA
40041
Mains fuse F1 (M 100 mA)
941571 0100
RC combination (0,1 µF/100 Ohm)
618 001 5100
Brass weight for probe installation
16 00 020901
Clamp for probe installation
16 00 101001
Event reporting system Phone Alarm SD1
90003