Set safety
Australia A
4.3.3 Safety Setting (Setting Country Code)
UP/DOWN Select
Safety
UP/DOWN
Password: 5432
Normal
Power=xxW
Setting
PtoGrid
ENT
ENT
ENT
Safety
Output P%
PassWord
xxxx
UP/DOWN Select
ON
ENT
Upstream
:
OFF
GroundLine
:
ON
Upstream
:
OFF
GroundLine
:
OFF
UP/DOWN Select
ON
Press ENT to confirm
ENT
DRM:ON
UP/DOWN
Password: 5432
UP/DOWN Select
Function Enable
ENT
ENT
Function Enable
Safety
PassWord
xxxx
UP/DOWN Adjustment
Safety
Press ENT to confirm
If GroundLine is not turned on, it cannot detect whether the
machine is grounded. After GroundLine and DRM functions are
turned on, the power must be cut off before normal use. If the
machine display shows Ground Wire Lost, it means that the
machine is not connected to the ground wire.
UP/DOWN Select
Setting
ENT
ENT
Operation
32
Note:
Note:
For compliance to AS/NZS
4777.2:2020, please select Region
from Australia A, B, C or New
Zealand. Please contact your local
grid operator on which Region to
select.