![Afore BNT KTL Series Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/afore/bnt-ktl-series/bnt-ktl-series_user-manual_2864719025.webp)
24
Electrical Specifications
BNT017KTL
BNT020KTL
Input (DC)
Max DC Power (W)
18700
22000
Max DC Voltage (V)
1000
1000
Rated/Recommended Voltage (V)
620
620
MPPT DC Voltage Range (V)
300
~
800
300
~
800
Start up DC Voltage (V)
320
320
Turn off DC Voltage (V)
300
300
Max DC Current (A)
21*2
22*2
Isc PV (A)
26*2
27.5*2
Number of MPPT Tracker
2
2
Number of DC connections (set)
4
4
Max Backfeed Current (mA)
<
1
<
1
Output (AC)
Power Connector
3P+N+PE/3P+PE
Max AC Power (W)
18250
21450
Nominal AC Power (W)
17000
20000
Max.AC Current (A)
30
32
Nominal AC Current (A)
25
29
Max AC Inrush Current (A)
25
29
Max AC Fault Current (A)
37.5
43.5
Max AC Protect Current (A)
37.5
43.5
Nominal AC Voltage (V)
230/400
Nominal AC Frequency (Hz)
50 / 60
Power Factor
-0.95
~
+0.95
Output current THD
<3%
Feed in Starting Power(W)
>
20
Power consumption
Power consumption at Night (W)
<1
<1
Power consumption at Standby
(W)
<15
<15
Power Efficiency
Max.Efficiency
98.50%
98.50%
Euro Efficiency
98.10%
98.10%
MPPT Efficiency
>
99.9%
>
99.9%
Safety and protection
Safety Standard
EN/IEC 62109-1/-2
EMC Standard
EN/IEC 61000-6, EN/IEC 61000-3
Anti-islanding Protection
Internal
General information
Dimensions (H
×
W
×
D) [mm]
680*345*170
Enclosure
IP65
Содержание BNT KTL Series