plug connectors provided. You will find the necessary DC plug connector for DC connection in the package.
To assemble the DC plug connectors, proceed as detailed below. Ensure the plug connectors have the
correct polarity.
The plug connector in DC side includes male and female as blow.
Please note that the sizes of metal connecting tubes are different. The bigger one is for female connector
and the smaller one is for male connector.
Assembly Instructions:
◆
Prepare the DC wire to connect the positive and negative DC arrays. Stripping length is 12
~
15mm
,
sectional area is 4 mm
2
as below.
◆
Insert the DC wire to metal connecting tube. Make sure all line heads are in the connecting tube as
picture blow.
Female Connector
Male Connector
Stripping length is 12~15mm, sectional area is 4mm
2