28
Fig.14. View of the Data log tab
4.1.7. Once the flow meter has been set up:
- close the device communication channel with PC by pressing the
in
the upper left corner of the Monitor BUF (310) application window;
- close the Monitor BUF (310) application window;
- set the device to WORK mode: remove the jumper from the contact pair
for allowing the modification of service parameters. Seal the contact pair.
4.2. Pre-commissioning
4.2.1. Pre-commissioning shall be performed by representatives of the organi-
zation having the right to perform such works or by representatives of the
manufacturer.
4.2.2. After the installation of the flow meter, the pipeline is filled with the meas-
ured liquid. The flow meter's battery is connected, the flow meter is con-
nected to the computer and adjusted in accordance with the instructions
in section 4.1 of this manual.
4.2.3. The flow meter is ready for operation on initial start-up or after a long
interruption in operation after:
- A 30-minute flushing of the CP with fluid stream
- A 30-minute warm-up of the flow meter.
4.2.4. When commissioning the flow meter, check:
- The correct connection of the flow meter and the interacting equipment
according to the selected connection diagram
- The correctness of the set operating modes of the flow meter's universal
and logic outputs.
After commissioning, the SMC enclosure can be sealed to protect
against unauthorized access during operation.
Содержание BUF M
Страница 1: ...BATTERY POWERED ULTRASONIC FLOW METER AFLOWT BUF M VERSION BUF 310 OPERATION MANUAL ISO 9001 2015 ...
Страница 2: ...2 Manufacturer quality management system is certified to ISO 9001 2015 URL http www aflowt com ...
Страница 41: ...41 Fig 30 Closing the application ...
Страница 46: ...46 1 button 2 LCD 3 flow direction indicator 4 cover Fig A 2 Flow meter AFLOWT BUF M Front panel view ...
Страница 48: ...48 APPENDIX B Wiring diagrams Fig B 1 AFLOWT BUF M flow meter wiring diagram ...