33
For Technicians | AfiPass II Installation Guide
8.1
Opening Test Mode
Set the AfiPass II Controller Test Mode Operation as follows:
To open Test Mode:
1.
Disconnect the device from the power supply (J10).
2.
On the AfiPass II PC Board turn ON the following SW1 DIP Switches:
a.
SW1.1 (Buzzer),
b.
SW1.2 (Test Mode).
3.
Turn OFF the following SW1 DIP Switches:
a.
SW1.3,
b.
SW1.4
c.
SW 1.5.
4.
Connect the power supply (J10).
Indication: The display shows 'Test M'.
5.
Connect the
AfiPass II Technician Tool
pin connectors instead of the gates' connectors
(see Figure 17):
a.
The connector with the yellow, black, white, and blue wires connects to
J4
.
b.
The connector with the orange, brown, red, and green wires connects to
J5
.
Figure 17 – Technician Tool Connections in AfiPass II Controller
6.
Reconnect the power (by connecting the power cable to the J10 connector).