background image

 

3

Service Information...................................................................................... 8 
INSTALLATION AND OPERATION INSTRUCTIONS 

 

INTRODUCTION 

Thank you for purchasing your American Fibertek RT-913D multimode video transmitter with bi-
directional multi-protocol data and remote diagnostic interface. Please take a few minutes to read these 
installation instructions in order to obtain the maximum performance from this product. 
 

FUNCTIONAL DESCRIPTION 

The RT-913D operates as half of a transmitter / receiver pair for the transmission of high performance 
10 bit digital NTSC, PAL, RS170, or RS343 video signals. The RT-913D also supports up to three bi-
directional channels of RS485 (2 or 4 wire), RS422, RS232 or Manchester data. Switch selection 
allows for multiple data configurations in one of the following three formats: 
  

Channel 1: RS422 or RS232 data 
Channel 2: RS422 or RS232 data 
Channel 3: RS422 or RS232 data 

Or: 
 

Channel 1: RS422 or RS232 data 
Channel 2: RS485 (2 or 4 wire) or Manchester data  
Channel 3: RS422 or RS232 data 

Or: 
 

Channel 1: RS485 (2 or 4 wire) or Manchester data 
Channel 2: RS485 (2 or 4 wire) or Manchester data 
Channel 3: Not available in this configuration 

 

NOTE: This unit is shipped in the following default configuration. For other configurations, 
please refer to the DATA CONFIGURATION section for changes to the default switch settings.  
 

Channel 1: RS422 data 
Channel 2: RS485 (4 wire) or Manchester data  
Channel 3: RS232 data  

 
The RT-913D is designed to operate with the MR-913D or RR-913D video receiver with bi-directional 
data over one multimode fiber optic cable. 
 
The RT-913D multiplexes a single video input signal along with up to three data signals into a high 
speed serial data stream. This serial data stream modulates a laser at 1310 nm wavelength. The RT-
913D also detects and demultiplexes a return optical serial data stream signal containing up to three 
data channels at 1550 nm wavelength. The 913D Series product is designed to operate over an optical 
loss budget range of 0 to 12 dB. Refer to the data sheets for detailed performance specifications. 
 
The RS485 channel may be configured for 2-wire (half duplex) or 4-wire (full duplex) operation with or 
without biasing. Switch selectable internal 120 ohm terminations are available for RS422 or RS485 
data. 
 
This unit is designed for rack mounting in either of two American Fibertek subracks available. The 
subrack model numbers are SR-20/2 or SR-20D/2. Slide in rack mounting, detachable terminal blocks, 
and LED indicators provide for easy installation and monitoring of video, data, and optical power.  
 
The RT-913D is designed for rack mounting only. For a modular stand alone version please see the 
MT-913D. 
 
The RT-913D has a built in capability to be remotely monitored through the Afinety Remote Diagnostics 
System. A SR-20D/2 subrack and a RD-20D diagnostic card are required to facilitate this feature. 
Please refer to the SR-20D/2 and RD-20D Instruction Manuals for proper operation of this feature. 

Содержание RT-913D

Страница 1: ...Copyright 2005 American Fibertek Inc 0825JD Instruction Manual RT 913D Video Transmitter With Bi directional Multi Protocol Data And Remote Diagnostic Interface...

Страница 2: ...ion 4 Power Source 4 Power Connection 4 Fiber Connection 4 Video Input Connection 4 Data Input Output Connections 5 Typical System Data Connections 5 Data Configuration 5 RS485 Data Signals 6 Offset B...

Страница 3: ...l 3 RS232 data The RT 913D is designed to operate with the MR 913D or RR 913D video receiver with bi directional data over one multimode fiber optic cable The RT 913D multiplexes a single video input...

Страница 4: ...o the unit via a four finger backplane connector The RR 913D can be inserted into the subrack or removed from the subrack with power applied to the backplane FIBER CONNECTION The fiber optic connectio...

Страница 5: ...a Out of the copper device is connected to the Data In of the RT 913D The plus terminal of the copper device is connected to the plus terminal of the RT 913D and the minus is connected to the minus Th...

Страница 6: ...nsmitter devices to go into a high impedance Hi Z state This allows multiple transmitter devices to reside on the same wire pair The software must dictate a protocol that allows only one device to tra...

Страница 7: ...LED indicator is provided to monitor the data coming in from the fiber through the RT 913D and out onto the electrical interface The intensity of this indicator will vary with input data patterns howe...

Страница 8: ...n Material Authorization RMA number is required to send the products back in case of return All returns must be shipped prepaid This warranty is void if the products have been tampered with This warra...

Отзывы: