![Afag IRG 1-S Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/afag/irg-1-s/irg-1-s_translation-of-operating-and-installation-instructions_2864004013.webp)
R02.1
04/03/2020
Page 13
5.2
Troubleshooting and fault repair
Table 2:
Troubleshooting and fault repair
Fault:
Fault repair
Appliance not working
Check the mains voltage, check the fuses and
replace if necessary.
Is the controller input set correctly, are the
jumpers correct?
Conveyor not working
Check whether the right oscillation frequency
has been set, where necessary alter the set-
ting.
Check the mains frequency (50/60 Hz). The
oscillation frequency and the mains voltage
must conform to one another.
U
max
trimmer setting too low, set U
max
.
Conveyor vibrates too much, mag-
net knocking (noises)
Incorrect oscillation frequency setting. CAU-
TION! Magnet may have been destroyed by
overheating, or mechanically damaged by
knocking against something.
U
max
trimmer setting too high, reset U
max
if
necessary.
Magnet heats up
Incorrect mains voltage for magnet, check.
Incorrect oscillation frequency set, reset if
necessary.
6
Accessories
6.1
Fixture
Table 3:
Order data
Type
Designation
Order number
Fixture
for 1 IRG
50450178
for 2 IRG
50450179
for 1 IRG extended
50450145
for 2 IRG extended
50450147