![AEV Energia Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/aev/energia/energia_manual_2863909019.webp)
P
AG
. 24
Energia
Energia
Energia
Energia
Energia
Electronic Equipment
E
le
c
tr
o
n
ic
E
q
u
ip
m
e
n
t
E
le
c
tr
o
n
ic
E
q
u
ip
m
e
n
t
A
E
V
S
.
P
.A
V
I
A
D
E
L
L
A
T
E
C
N
I
C
A
N
.3
I
-
4
0
0
5
0
A
R
G
E
L
A
T
O
B
O
L
O
G
N
A
I
T
A
L
Y
W
W
W
.
A
E
V
.
N
E
T
W
W
W
.
A
E
V
-
U
S
A
.
C
O
M
E
-
M
A
I
L
:
I
N
F
O
@
A
E
V
.
N
E
T
START
When the START key is pressed, the following actions occur: the channel input signal is sent
to the PGM and/or UTL busses, if previously selected; the CUE function is disabled if it had
been enabled and any command that may have been associated with it is activated (see Tlc
setup).
STOP
When the STOP key is pressed, the following actions occur: the channel input signal is no longer
sent to the PGM and/or UTL busses, if they had been selected. Telco 1 and Telco 2 busses are
not influenced by the STOP. If previously enabled, the CUE function is disabled, and any command
that may have been associated with it is activated (see Tlc setup).
D ir e ct com m a n ds: Con t r ol Room Se ct ion
The level of the Control Room output can be varied with the C.Room potentiometer on the panel.
E
XT
1
When the EXT1 key is pressed, the following actions occur: the EXT1 input signal is sent to the
Control Room output, and the function previously set on the Control Room bar is disabled.
E
XT
2
When the EXT2 key is pressed, the following actions occur: the EXT2 input signal is sent to the
Control Room output, and the function previously set on the Control Room bar is disabled.
PGM
When the PGM key is pressed, the following actions occur: the PGM input signal is sent to the
Control Room output, and the function previously set on the Control Room bar is disabled.
UTL
When the UTL key is pressed, the following actions occur: the UTL input signal is sent to the
Control Room output, and the function previously set on the Control Room bar is disabled.
D ir e ct com m a n ds : Con t r ol St u dio Se ct ion
The level of the Control Studio output can be varied with the C.Studio potentiometer on the
panel.
E
XT
1
When the EXT1 key is pressed, the following actions occur: the EXT1 input signal is sent to the
Control Studio output, and the function previously set on the Control Studio bus is disabled.
E
XT
2
When the EXT2 key is pressed, the following actions occur: the EXT2 input signal is sent to the
Control Studio output, and the function previously set on the Control Studio bus is disabled.
PGM
When the PGM key is pressed, the following actions occur: the PGM input signal is sent to the
Control Studio output, and the function previously set on the Control Studio bus is disabled.
UTL
When the UTL key is pressed, the following actions occur: the UTL input signal is sent to the
Control Studio output, and the function previously set on the Control Studio bus is disabled.
CUE
When the CUE key is pressed, the following actions occur: the signal on the CUE bus is sent to
the Control Studio output, and the function previously set on the Control Studio bus is disabled.