IntelliTAP  Satellite / Remote Dialer Data Receiver

Page 11

40-0571

CENTRAL RECEIVER 

COMPATIBILITY and REQUIREMENTS

Central Receiver Compatibility:  

All current AES receivers 7000/2, 7000/1, 7099, 7701/Net77 and 7703 receivers will

accept TAP signals. Some earlier versions may require an upgrade. If there are any questions, have the central station contact

technical support at AES Corporation at tel 978-535-7310.

7000 Series (7000/2, 7000/1 and 7099)

 require version CEN 1.71 network controller board and version ALM 1.72 alarm

output or higher. These receivers will print the TAP messages on the event printer and pass the signal to alarm automation

properly.

7701 with 7700 and Net77 software requires

 Net77 version 1.48.4CT, 1.48.4CTD, 1.48.30 or later.

Important Note: 

The 7701 receiver with firmware of 1.65 or earlier will not print TAP messages on the event printer. If

Net77 is not running for any reason, the TAP alarm cannot be reported. Thus it is mandatory that at least one zone of the

Subscriber Unit must be activated for any system using the 7701 receiver with 1.65 or earlier firmware.
• For Net77 version 1.48.30, TAP messages are sent out the automation port with all other signals.
• For Net77 version 1.48CT and 1.48CTD send TAP messages to automation out Com port 3.

All AES 7703 and KELTRON RF7300 Receivers 

are compatible with the TAP.

Note: The automation output will send Contact ID information from the alarm panel, including the panel ID number. In a line

cut situation, the Subscriber ID number is used.

FCC Compliance

This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions: (1)

This device may not cause harmful interference, and (2) This device must accept any interference received

including interference that may cause undesired operation.

UL / cUL Compliance Notes

• Only Contact ID format has been evaluated by UL.

• The 7068 IntelliTAP unit has been investigated by UL for Supplemental Use Only.

• The 7068 IntelliTAP unit must be mounted inside the AES Subscriber Unit.
The 7068 IntelliTAP unit has been evaluated to the following Standards:

USL:

UL 609 (10th ed) - Local Alarm Units and Systems

UL 365 (4th  ed) - Police Station Connected Burglar Alarm Units and Systems

UL 1610 (2nd ed) - Central Station Burglar Alarm Units

UL 864 (8th ed) - control Units for Fire-Protective Signaling Systems

CNL:

CAN/ULC-S527-M87 (1st ed) - Standard for Control Units for Fire Alarm Systems (amend 1995)

ULC Subject C1023-1974 (1st ed) - Preliminary Standard for Household Burglar Alarm System Units

CAN/ULC-S545-M89 (1st ed) - Standard for Residential Fire Warning System Control Units (amended 1995)

CAN/ULC-S303-M91 (1st ed) - Standard for Local Burglar Alarm Units and Systems

CAN/ULC-S304-M88 (1st ed) - Standard for Central and Monitoring Station Burglar Alarm Units

ORD-C1076-1986 (5th ed) - Proprietary Burglar Alarm Units and Systems

Electrical Rating: 12VDC nominal
Current: Typical: 50ma  

(no load on ERR or IP outputs)

Maximum: 450ma 

(with max load on ERR and IP outputs)

Содержание 7068

Страница 1: ...4 Tap with Phone Line RJ31X 5 Figure 5 Tap with Phone Line w o RJ31X 6 Figure 6 Tap with No Phone Line 6 Figure 7 Tap No Phone Line Can t Blind Dial A 6 Figure 8 Tap No Phone Line Can t Blind Dial B...

Страница 2: ...F 7450 Radio Subscriber Units with Version ESB SUB 1 71 or later Central Receiver Compatibility 7000 2 7000 1 7099 7701 Net77 and 7703 receivers will accept TAP packets Some earlier versions may requi...

Страница 3: ...format has been evaluated by UL 3 1 4 1 4 2 format with 1400Hz answer tone Jumper on 2 only 3 1 4 1 4 2 format with 2300Hz answer tone Jumper on 3 only Note For 3 1 4 1 4 2 program your alarm panel f...

Страница 4: ...rm panel dialer phone number with the digits 5 5 5 During a reported event the phone line is quiet after the 5 5 5 is dialed as it waits for more digits During this period the TAP provides an answer t...

Страница 5: ...th NA Yes pg7 RJ31X Check capabilities of Alarm Panel A t t a c h t o P h o n e L i n e A l a r m P a n e l C a n B l i n d D i a l I n s t a l l a t i o n R e q s D e t e c t i o n o f T o n e S o u...

Страница 6: ...m the panel with the phone number 5 5 5 Make sure there is NO jumper on position 5 Test the setup by generating an event on the alarm panel 1 2 3 4 5 6 T R T1 R1 Figure 6 AES 7068 INTELLITAP ALARM PAN...

Страница 7: ...that the TAP can differentiate between a house phone off hook and an alarm panel dialing If this works as described here proceed to the next step If this test provides different results check wiring t...

Страница 8: ...enough outputs you can send general alarms for more specific clarification such as General Fire Burglary Panic etc The backup zone activation is immediate and will likely activate faster than the TAP...

Страница 9: ...2 Figure 13 Important Note Observe polarity when connecting to ERR or IP outputs Incorrect connections of output can damage the 7068 circuit board Open Collector Open Collector 12V IP Output for Alarm...

Страница 10: ...f data from the alarm panel to the TAP Here is a typical wiring diagram R1 T1 R T RJ31X JACK TIP RING TERMINALS ON ALARM CONTROL PANEL PREMISES PHONES INCOMING PHONE LINE 1 2 3 4 5 6 BROWN T TIP RING...

Страница 11: ...te The automation output will send Contact ID information from the alarm panel including the panel ID number In a line cut situation the Subscriber ID number is used FCC Compliance This device complie...

Отзывы: