. Connection Explanation: 

 

Connecting the DC power in the wrong way (reverse polarity) will destroy the power

 

 

 

   

 

 

 

 

 

 

 

 

 

inverter and may damage the electrical equipment in use, please follow the steps below

 

 

 

 

 

 

   

 

 

 

 

 

 

in the correct sequence and make sure to use the inverter in the correct way. 

   

 

 

1. There is one red cable and one black cable for the battery. Screw tightly red 

cable with inverter’s “+” and battery’s “+” terminal. 

2. Screw tightly black cable with inverter’s “­” and battery’s  “­” terminal; please

 

 

 

don’t reverse the polarity or it will damage the inverter and/or battery. 

3. Turn on the inverter switch, green light should come on 
4. Insert the plug of desired electrical appliance into the AC output socket of

 

 

 

 

 

 

 

 

 

 

 

 

 

inverter. 

Note: For better operation, we recommend consumer to use with battery that exceeds

 

 

 

 

 

 

   

 

 

 

 

 

100AH. 

 

 
 
 
 
 
 
 

. Application 

 

1)  Scope of application: 

   a) Only use for class 

 appliances 

Electric power tool series

Electric Saw, Drill, Sander etc..   

Office equipment: Computers, printers, displays, scanners, facsimile apparatus

 

Household appliances: Vacuum cleaner, fan, fluorescent lamp, filament lamp,

 

 

 

 

 

 

 

 

 

sewing machine; 
Kitchen series: Microwave oven, refrigerator, freezer, coffee machine, blender,

 

 

 

 

 

 

 

 

 

ice machine; hot oven; 
Commercial installation series: Metal halogen light, watercraft, cars, solar energy

 

 

 

 

 

 

 

 

 

 

and wind power generation. 
Electric Field series: TV, radio, game player, VCR, power amplifier; monitoring

 

 

 

 

 

 

 

 

 

 

 

equipment, satellite communication equipment. 

 
 
 
Note: While using please follow the related power of the inverter. Do not over load the

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

inverter. It is better to keep the inverter working at 85% of it's related power. 

 
 
 
 
 
 

 

Содержание FTS600P

Страница 1: ...DC TO AC POWER INVERTER INSTRUCTION MANUAL FTS600P FTS800P FTS1200P Applicable for 600W 800W 1200W ...

Страница 2: ... input under voltage protection input over voltage protection overload protection over temperature protection output short circuit protection Please read this carefully before using Features and Application Pure sine wave output High efficient and portable Intelligent fan control Advanced microprocessor design With low voltage high voltage overload short circuit and overheat protection Ⅱ Products ...

Страница 3: ...t of inverter Note For better operation we recommend consumer to use with battery that exceeds 100AH Ⅳ Application 1 Scope of application a Only use for class Ⅱ appliances Electric power tool series Electric Saw Drill Sander etc Office equipment Computers printers displays scanners facsimile apparatus Household appliances Vacuum cleaner fan fluorescent lamp filament lamp sewing machine Kitchen ser...

Страница 4: ...rge with the inverters USB port 2 Usage a The inverters input voltage must be same as battery s voltage The appliance s working voltage must be same as inverters output voltage once all are the same connect them in right way based on Connection Explanation of the manual b Please use the inverter in ventilated areas and make sure the fan is not blocked c Do not put the inverter in rain or in humid ...

Страница 5: ...n using in cars please don t run the inverter while the engine has stopped 4 Please do not open the inverter for service please use a professional to mend it Ⅴ Safety 1 Please do not operate the inverter while your hands are wet Keep it away from children 2 The temperature of the shell will be high after extended use so do not touch it in case of scalding 3 Do not put metal objects into the invert...

Страница 6: ...e battery returns to the related voltage the inverter will start working green light will go on red light will go off Over load protection Green on Red on No alarm No AC output Reduce the load to acceptable range theinverter will start working green light will go on red light will go off Over temperature shut down Green on Red on Alarm No AC output When the inside temperature returns to acceptable...

Страница 7: ... rate 3 Effiency 85 No load current 0 95A Input under voltage alarm 12V input DC 10 2 10 8V Input under voltage shut down 12V input DC 9 2 9 8V Input over voltage shut down 12V input DC 15 16V Overload shut down 660W 780W 960W 1060W 1300W 1500W Working temperature 5 35 Heat dissipation method fans Cable Red Black Battery Cable Technical Assistance If you need assistance Aerpro Inverter now or in t...

Отзывы: