background image

26

26

27

C

H

A

P

T

ER
 2

  

l

  

O

PE
R

A

TI
O

N

C

H

A

P

T

ER
 2

  

l

  

O

PE
R

A

TI
O

N

AUTO-RESTART

Auto-Restart feature helps ensure that your vehicle will be charged and ready for use when needed. If a 
charge is interrupted due to a temporary error condition, the Charging Dock automatically clears any error 
codes when the cause of the temporary error condition returns to normal and then attempts to restart 
the charge. The TROUBLE light remains lit while the cause of the temporary error condition is active or 
awaiting a time-out delay.

The exception to immediate Auto-Restart is when the interrupt is due to a GFCI event.  
To allow charging after GFCI events caused by line surges or other disturbances, the  
Charging Dock will restart 15 minutes  
after a GFCI event if the event did not occur 
immediately upon connecting power to the 
vehicle. The Charging Dock is limited to four 
automatic restarts after a GFCI event during 
a charge cycle. After the fourth attempt, the 
Charging Dock will shut down and the  
TROUBLE light will be ON.

pdf pg 15

POWER PRESENT

READY TO CHARGE

VEHICLE CONNECTED

VEHICLE CHARGING

TROUBLE

THIS LIGHT GOES OUT WHEN  
AUTO-RESTART IS SUCCESSFUL

POWER OUTAGE RECOVERY

If there is a power outage, the utility grid might experience a large surge from multiple 
Charging Docks in your area attempting to resume charging simultaneously when power 
is restored. This would cause additional stress to the utility grid. The “Power Outage 
Recovery” feature avoids this scenario by resuming charge with an automatic delay 
after restoration of power. Power Outage Recovery ensures that Charging Dock  
users in your area will resume charging in a staggered fashion to avoid stressing the 
grid. If a utility power outage occurs while your vehicle is being charged, the Charging 
Dock will automatically resume charging once power is returned. The VEHICLE 
CHARGING light blinks and  
charging will re-start automatically  
after a randomly assigned time  
ranging from 0 to 20 seconds.

pdf pg 15

POWER PRESENT

READY TO CHARGE

VEHICLE CONNECTED

VEHICLE CHARGING

TROUBLE

BLINKS  

AFTER POWER 

IS RESTORED

Содержание EV Solutions EVSE-RS Plug-in

Страница 1: ...TRICIAN Leave this User Guide with the EVSE RS customer for future reference Model EVSE RS Plug In not for outdoor installation USER GUIDE 100 electric AeroVironment EV Solutions Charging Dock Model E...

Страница 2: ...EVSE RS Plug in are repre sentative production models may vary No portion of these materials may be duplicated used or disclosed without prior written permission from AeroVironment Inc Disclaimer This...

Страница 3: ...DEL EVSE RS Plug in SERIAL NUMBER S N On label on underside of Charging Dock enclosure housing PURCHASE DATE TABLE OF CONTENTS GETTINGSTARTED 1 Introduction 2 Electricvehiclecompatibility 3 Features 3...

Страница 4: ...CHAPTER 1 GETTING STARTED iv iv...

Страница 5: ...t is for indoor use ONLY It is recommended that the unit be wall mounted 2 C H A P T E R 1 l G E T T I N G S T A R T E D 3 C H A P T E R 1 l G E T T I N G S T A R T E D ELECTRIC VEHICLE COMPATIBILITY...

Страница 6: ...ixed to your Charging Dock IMPORTANT SAFETY INSTRUCTIONS Please read these important safety instructions and the charging instructions in your vehicle owner s manual before charging your electric vehi...

Страница 7: ...e To clean the Charging Dock wipe the Charging Dock with a clean cloth dampened with water or a mild detergent solution suitable for use on automobile paint Turn off power at the circuit panel before...

Страница 8: ...fects or other reproductive harm CAUTION To reduce the risk of electric shock connect only to properly grounded outlets ALWAYS position the Charging Dock output cable so that it will not be driven ove...

Страница 9: ...evice complies with Part 15 of the FCC Rules Operation is subject to the following two conditions This Class B digital apparatus complies with Canadian ICES 003 1 This device may not cause harmful int...

Страница 10: ...d with excessive force The Charging Dock cable should be coiled up on the hanger when not in use to minimize potential cable damage and to eliminate the possibility of tripping over the cable If the c...

Страница 11: ...CHAPTER 2 OPERATION 14 C H A P T E R 1 l G E T T I N G S T A R T E D...

Страница 12: ...nterrupts the charging cycle at any time If vehicle is connected to the Charging Dock press START to resume charging STORAGE Connector inserts into Charging Dock here and stays in place for storage wh...

Страница 13: ...connector from the Charging Dock CHARGING YOUR VEHICLE 1 CHECK INDICATOR LIGHTS First make sure the POWER PRESENT and READY TO CHARGE lights are ON as shown below This means that the Charging Dock is...

Страница 14: ...time if the driver has set a vehicle charging timer for scheduled charging POWER PRESENT VEHICLE CONNECTED and the VEHICLE CHARGING lights stay on when charging VEHICLE CHARGING light blinks when the...

Страница 15: ...interrupt charging at any time using one of the two following methods If you want to temporarily stop charging and restart later without having to remove the coupler then the buttons are the preferre...

Страница 16: ...esume charging pdf pg 15 POWER PRESENT READY TO CHARGE VEHICLE CONNECTED VEHICLE CHARGING TROUBLE STOP PAUSE START RESUME BLINKING OFF LATCH RELEASE 7 REMOVE AND RETURN CONNECTOR TO CHARGING DOCK When...

Страница 17: ...ter the fourth attempt the Charging Dock will shut down and the TROUBLE light will be ON pdf pg 15 POWER PRESENT READY TO CHARGE VEHICLE CONNECTED VEHICLE CHARGING TROUBLE THIS LIGHT GOES OUT WHEN AUT...

Страница 18: ...ng Dock TIME OF USE METERING Many electric utilities have been actively promoting the use of EVs and have developed specific utility rates to promote off peak charging of these vehicles This allows th...

Страница 19: ...ice on the Charging Dock or the Charging Dock Warranty may be invalidated Contact Customer Support for service NOTE NOTE 30 31 C H A P T E R 3 l T R O U B L E S H O O T I N G POWER PRESENT LIGHT DOES...

Страница 20: ...the panel and discontinue using immediately and contact Customer Support for service 3 Inspect vehicle receptacle for damage If damaged discontinue using immediately and report the problem to your nea...

Страница 21: ...not deliver power to the vehicle The problem must be corrected before charging starts or resumes There are two scenarios for a solid TROUBLE light NOTE 1 Turn power OFF then ON at circuit breaker or...

Страница 22: ...eat source 3 Provide shade from direct sunlight 4 If the fault persists contact Customer Support for service TROUBLE LIGHT IS RAPIDLY BLINKING Press STOP A TROUBLE LIGHT GOES OFF 1 Press START 2 TROUB...

Страница 23: ...CHAPTER 4 INSTALLATION C H A P T E R 3 l T R O U B L E S H O O T I N G 38...

Страница 24: ...ply with the provisions of the National Electric Code NEC and all local codes for the U S or must comply with Canadian Electric Code for Canada Charging Dock must be installed using 1 40 amp circuit b...

Страница 25: ...CHAPTER 5 APPENDIX 42 C H A P T E R 4 l I N S T A L L A T I O N...

Страница 26: ...HIS LIMITED WARRANTY AND ANY REQUIRED WARRANTIES ARE LIMITED IN DURATION TO THE WARRANTY PERIOD To the extent permitted by applicable laws a AV s total warranty expense with respect to any Charging Do...

Страница 27: ...g 44 F features 3 17 front panel cover 16 G ground fault circuit 11 I installing 6 39 L latch release 17 19 20 25 M model ii N NEMA Type 3R 44 O owner s record ii P power outage recovery 27 R regulato...

Страница 28: ...Customer Support Phone Number US 1 877 NO GAS EV 1 877 664 2738 Canada 1 800 387 0122 100 electric 21327 03 Rev 2...