FULL-SPEED FAN START-UP
In order to overcome the inertia of the ventilation system components and
de-ice the fan blades in cold weather conditions, the controller supplies
maximum voltage to the variable speed fans for 2 seconds immediately
following each start-up.
FOUR INDEPENDENT TEMPERATURE PROBE INPUTS
Up to four temperature probes can be connected to the controller in order to
obtain a more accurate reading of the average room temperature and a
faster reaction time.
OVERLOAD AND OVERVOLTAGE PROTECTION
Fuses are installed at the input and outputs of the controller to protect its
circuitry in the case of an overload or overvoltage.
COMPUTER CONTROL
The controller can be connected to a computer, thus making it possible to
centralize the management of information and diversify control strategies.
CONTROL OF AIR INLET MOVEMENT
If the ST 5110 is used in combination with a SB 2000 controller, the move-
ment of the air inlets can be coordinated with the operation of the fans using
a potentiometer located on the curtain machine or baffle actuator. This
allows the air inlets to be adjusted correctly, without the influence of uncon-
trollable factors such as wind or air from adjoining rooms. When tunnel
ventilation is being used, the SB 2000 closes the air inlets.
HIGH/LOW TEMPERATURE ALARM OUTPUT