Installation and Configuration
Soloist Hardware Manual
2-6
www.aerotech.com
2.5
Typical AC Wiring with the -AUXPWR Option and an
External Transformer
To generate a 40, 80 160 VDC Bus for the motor power, connect your Soloist to a
115/230 VAC source. The following three figures illustrate the six combinations available
for both AC input voltages and all three DC bus voltages when the -AUXPWR option is
used.
TV0.3-28 WIRING
PRIMARY = 115VAC
SECONDARY = 28VAC (40VDC BUS)
TRANSFORMER P/N EAX01007
TV0.3-28 WIRING
PRIMARY = 230VAC
SECONDARY = 28VAC (40VDC BUS)
TRANSFORMER P/N EAX01007
4
AUXPWR OPTION
Soloist
splice
PRIMARY FUSE
YEL 28v
FRAME GROUND
BLK 0v
115v BRN
100v GRN
0v BLU
RED 28v
TRANSFORMER
INTERNAL
THERMAL
SWITCH
GRN 0v
0v GRAY
#18 WHT
100v ORN
115v BLK
#18 WHT
3
splice
splice
3
3A SLO-BLO
SAFTEY
AC LO
AC HI
AUXPWR OPTION
4
Soloist
FRAME GROUND
YEL 28v
BLK 0v
0v BLU
100v GRN
115v BRN
0v GRAY
splice
2
PRIMARY FUSE
splice
RED 28v
GRN 0v
TRANSFORMER
THERMAL
SWITCH
INTERNAL
115v BLK
100v ORN
#18 WHT
#18 WHT
2
4A SLO-BLO
AC HI
SAFTEY
AC LO
Soloist
AUXPWR INTERCONNECT
(40VDC BUS / TV0.3-28)
620B1346-1
620B1346-101.DWG
NOTES:
1. THE AUXPWR OPTION IS USED WHEN THE MAIN SUPPLY POWER IS BELOW
100VAC. TYPICALLY 28-56VAC INPUT. THIS COREESPONDS TO A BUS
VOLTAGE OF 40-80VDC.
2. FOR 100VAC PRIMARY INPUT, PARALLEL THE 100VAC TAPS AND LEAVE
THE 115VAC TAPS UNTERMINATED.
3. FOR 200VAC PRIMARY INPUT, SERIES THE 100VAC TAPS AND LEAVE THE
115VAC TAPS UNTERMINATED.
4. WHEN USING AN ISOLATION TRANSFORMER, EARTH GROUNDING OF THE
"AC2" INPUT TAP REDUCES ELECTRICAL AND AUDIBLE NOISE EMMISSIONS
AND PROVIDES INCREASED SERVO PERFORMANCE.
5. IT IS RECOMMENDED THAT THE OPTIONAL AND MAIN SUPPLIES ARE
CONNECTED TO THE SAME SOURCE AS SHOWN. THIS WILL ENSURE PROPER
SOFT START OPERATION.
6. ADDITIONAL OR ALTERNATIVE FUSING MAY BE REQUIRED FOR OPTIMUM
PROTECTION.
O
P
T
IO
N
A
L
S
U
P
P
L
Y
AC2
AC1
M
A
IN
S
U
P
P
L
Y
AC1
AC2
INPUT
50/60 HZ
115VAC
M
A
IN
S
U
P
P
L
Y
O
P
T
IO
N
A
L
S
U
P
P
L
Y
AC2
AC1
AC2
AC1
INPUT
50/60 HZ
230VAC
Figure 2-2
40 Volt DC Bus from 115 and 230 VAC Source
Figure 2-2 is shown only for reference. For the most recent .Dwg files, see your
software CD ROM, which includes a .Dwg file viewer.
Содержание SOLOIST
Страница 20: ...Introduction Soloist Hardware Manual 1 10 www aerotech com...
Страница 50: ...Technical Details Soloist Hardware Manual 3 6 www aerotech com Figure 3 3 User Outputs J104...
Страница 77: ...Soloist Hardware Manual Soloist Options www aerotech com 4 13 Figure 4 10 Suppression for DC Brake Systems...
Страница 78: ...Soloist Options Soloist Hardware Manual 4 14 www aerotech com...
Страница 88: ...Accessories Soloist Hardware Manual 5 10 www aerotech com...
Страница 96: ...Troubleshooting Soloist Hardware Manual 6 8 www aerotech com...
Страница 114: ...Index Soloist Hardware Manual iv www aerotech com...
Страница 116: ......