3.4. Opto Out Connector (Digital Outputs) (TB204)
The digital outputs are optically-isolated and can be connected in sourcing or sinking configurations. The
digital outputs are designed to connect to other ground referenced circuits and are not intended to provide
high-voltage isolation.
The outputs are software-configurable and must be connected in either all sinking or all sourcing mode.
and
illustrate how to connect to an output in current sourcing and current sinking
modes.
The opto-isolator's common connections can be directly connected to the drive's power supply; however,
doing so will effectively defeat the isolation and will reduce noise immunity.
Table 3-11:
Digital Output Specifications (TB204)
Opto Device Specifications
Value
Maximum Voltage
24 V maximum
Maximum Sink/Source Current
60 mA/channel @ 50°C
Output Saturation Voltage
2.75 V at maximum current
Output Resistance
33 Ω
Rise / Fall Time
250 usec (typical)
Reset State
Output Off (High Impedance State)
N O T E :
Power supply connections must always be made to both the Output Common Plus (OP) and
Output Common Minus (OM) pins as shown in
and
Table 3-12:
Opto Out Connector Pinout (TB204)
Pin#
Description
In/Out/Bi
1
Digital Output Common Plus
Input
2
Digital Output Common Minus
Input
3
Digital Output 0 (Optically-Isolated)
Output
4
Digital Output 1 (Optically-Isolated)
Output
5
Digital Output 2 (Optically-Isolated)
Output
6
Digital Output 3 (Optically-Isolated)
Output
7
Digital Output 4 (Optically-Isolated)
Output
8
Digital Output 5 (Optically-Isolated)
Output
9
Digital Output 6 (Optically-Isolated)
Output
10
Digital Output 7 (Optically-Isolated)
Output
Table 3-13:
Mating Connector Part Numbers for the Opto Out Connector (TB204)
Aerotech P/N
Phoenix P/N
Wire Size: mm
2
[AWG]
10-Pin Terminal Block
ECK01294
1881406
0.5-0.080 [20-28]
Suppression diodes must be installed on outputs driving relays or other inductive devices. This protects the
outputs from damage caused by inductive spikes. Suppressor diodes, such as the 1N914, can be installed
on all outputs to provide protection. It is important that the diode be installed correctly (normally reversed
biased). Refer to
for an example of a current sinking output with diode suppression and
for an example of a current sourcing output with diode suppression.
Soloist MP
-IO Expansion Board
Содержание Soloist MP 10
Страница 1: ...Revision 4 10 00 Soloist MP Hardware Manual...
Страница 6: ...Soloist MP Table of Contents 6 www aerotech com This page intentionally left blank...
Страница 14: ...Soloist MP Quick Installation Guide 14 www aerotech com This page intentionally left blank...
Страница 60: ...Soloist MP Installation and Configuration 60 Chapter 2 www aerotech com This page intentionally left blank...
Страница 69: ...IO Expansion Board Soloist MP Figure 3 6 Digital Opto Isolated Outputs IO Board www aerotech com Chapter 3 69...
Страница 72: ...72 Chapter 3 www aerotech com Figure 3 9 Digital Opto Isolated Inputs Soloist MP IO Expansion Board...
Страница 75: ...IO Expansion Board Soloist MP Figure 3 12 Auxiliary Encoder Channel J201 www aerotech com Chapter 3 75...
Страница 77: ...IO Expansion Board Soloist MP Figure 3 13 PSO Interface www aerotech com Chapter 3 77...
Страница 78: ...Soloist MP IO Expansion Board 78 Chapter 3 www aerotech com This page intentionally left blank...
Страница 81: ...Accessories Soloist MP Figure 4 2 Two Axis Joystick Interface www aerotech com Chapter 4 81...
Страница 86: ...86 Chapter 5 www aerotech com Soloist MP Maintenance This page intentionally left blank...
Страница 90: ...Soloist MP Revision History 90 Appendix B www aerotech com This page intentionally left blank...
Страница 94: ...Soloist MP Index 94 www aerotech com This page intentionally left blank...