![Aerotech Soloist CP 10 Скачать руководство пользователя страница 93](http://html1.mh-extra.com/html/aerotech/soloist-cp-10/soloist-cp-10_hardware-manual_2863050093.webp)
-IO Expansion Board
Soloist CP
3.5. Relay Connector (TB206)
The relay can be used to automatically control a fail-safe brake on a vertical axis. It can also be used as a
general purpose relay. The normally-open relay contacts are accessible through TB206 and the Motor
Feedback (J103) connector. The normally-closed relay contact is only accessible through TB206 (see
). The Motor Feedback connector allows the brake wires to be included in the motor feedback cable and
eliminate the need for a separate brake cable.
The brake output can be software configured; refer to the Soloist Help file for more information (see topics for
the EnableBrakeControl parameter and the BRAKE command).
When TB206 is used to power the mechanical brake control relay, the solid state brake control relay (TB103)
should not be used.
The user must verify that the application will be within the specifications of the Brake/Relay contacts.
Table 3-19:
Voltage and Current Specifications (TB206)
Relay K1 Contact Ratings
Maximum Switched Voltage
150 VDC, 125 VAC
Maximum Switched Current
1A
Maximum Carrying Current
1A
Maximum Switched Power
30 W (DC), 60 VA (AC)
N O T E :
The maximum power that may be switched is voltage dependent.
Initial Contact Resistance
50 milliohms max @ 10 mA, 6 VDC
N O T E :
Do not exceed Maximum Current or Maximum Power specifications.
Table 3-20:
Relay Connector Pinout (TB206)
Pin#
Description
In/Out/Bi
1
Brake Relay Output Normally Closed Contact
Output
2
Brake Relay Output Common Contact
Output
3
Brake Relay Output Normally Open Contact
(1)
Output
(1) For JP1 jumper configuration, refer to
Table 3-21:
Mating Connector Part Numbers for the Relay Connector (TB206)
Type
Aerotech P/N
Phoenix P/N
Wire Size: AWG [mm
2
]
4-Pin Terminal Block
ECK01293
1881341
20-28 [0.5- 0.080]
The configuration of JP1 (
) allows either the Brake + or the Brake - output to be switched by the
relay and connected at the Motor Feedback connector or for the brake to be connected at TB206. Refer to
for more information. JP1 is located on the -IO board (refer to
).
Table 3-22:
-IO Expansion Board Brake Jumper Configuration
Jumper
Setting
Description
JP1
1-2, 3-4
Switch Brake +
5-6, 7-8
(1)
Switch Brake -
1-3
Relay Only
(1) default
www.aerotech.com
Chapter 3
93
Содержание Soloist CP 10
Страница 1: ...Revision 4 09 00 Soloist CP Hardware Manual...
Страница 14: ...Soloist CP Quick Installation Guide 14 www aerotech com This page intentionally left blank...
Страница 24: ...Soloist CP Introduction 24 Chapter 1 www aerotech com This page intentionally left blank...
Страница 65: ...Installation and Configuration Soloist CP Figure 2 34 PSO Interface www aerotech com Chapter 2 65...
Страница 80: ...Soloist CP Installation and Configuration 80 Chapter 2 www aerotech com This page intentionally left blank...
Страница 87: ...IO Expansion Board Soloist CP Figure 3 4 Digital Outputs TB202 TB203 www aerotech com Chapter 3 87...
Страница 90: ...90 Chapter 3 www aerotech com Figure 3 7 Digital Inputs Soloist CP IO Expansion Board...
Страница 100: ...100 Chapter 4 www aerotech com Soloist CP Accessories This page intentionally left blank...
Страница 108: ...Soloist CP Revision History 108 Appendix B www aerotech com This page intentionally left blank...