![Aerotech OD301MNZ Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/aerotech/od301mnz/od301mnz_manual_2863150008.webp)
8
14
PWR MD
TEMP
Power Module Board Temperature.
15
MAX
BOARD
Maximum Temperature recorded on any
Board.
(Push “
CLEAR
” to reset value)
16
CAVITY
TEMP
The Cavity Temperature measured by
the sensor.
17
FAULT
CODE
The two most recent Fault Codes are
displayed.
(Refer to Note 1)
18
NUM
DAYS
Shows the number of days the product
has been on.
19
DOWN
LOAD
Shows that data can now be
downloaded.
(Press “
CLEAR
” to begin Smart Tool
Download)
Note 1:
When “FAULT CODE” is selected, the oven temperature display will show the two most
recent fault codes in the following temperature knob positions. If “OFF” is displayed, then
there are no faults logged.
Temperature Knob Position
Description
0
Most Recent Fault
1
2
nd
Most Recent Fault
If the same fault occurs consecutively it will only be recorded as one fault.
If the Most Recent Fault code is cleared from the log it will then be recorded
as the 2
nd
Most Recent Fault. The Most Recent Fault position will be left
blank.
Note:
To clear a fault code from the log push
CLEAR
when it is displayed in
the temperature display.
Accessing Technical Data Log
(a)
Enter Technician Mode (refer to previous page).
(b)
Choose Tech Select option “DOWN LOAD”
(c)
Hold the Fisher & Paykel “Smart Tool” download pen up to the clock
module display (top left corner) to initiate download.
(d)
Data can now be viewed on the PC.