Installation and Configuration
Ndrive QL Hardware Manual
2.2. Electrical Installation
The Ndrive QL has one AC input power connector. For a complete list of electrical specifications, refer to
Section 1.1. Electrical Specifications
.
2.2.1. Power Input (TB101)
AC input power to the QL is applied to the Input Power (TB101) connector.
The connection requires a minimum of 100 VAC input to operate properly. The AC1 and AC2 inputs are
internally fused.
shows the required connections to the control power input.
POWER INPUT
AC1
AC2
TB101
100-240V~
50/60Hz
2A MAX
Figure 2-1:
Power Input Connections
Table 2-1:
Power Supply Wiring (TB101)
Pin
Description
Recommended Wire Size
AC1
100 - 240 VAC Input Range
1.3 mm
2
(#16 AWG)
AC2
100 - 240 VAC Input Range
1.3 mm
2
(#16 AWG)
Protective Ground (Required for Safety)
1.3 mm
2
(#16 AWG)
Type
Aerotech P/N
Phoenix P/N
Screw Torque
Value: Nm
Wire Size:
AWG [mm
2
]
3-Pin Terminal Block
ECK00213
1754465
0.5 - 0.6
12-30 [3.3 - 0.516]
20
Chapter 2
www.aerotech.com
Содержание Ndrive QL Series
Страница 6: ...Table of Contents Ndrive QL Hardware Manual 6 www aerotech com This page intentionally left blank...
Страница 10: ...Declaration of Conformity Ndrive QL Hardware Manual 10 www aerotech com This page intentionally left blank...
Страница 12: ...Quick Installation Guide Ndrive QL Hardware Manual 12 www aerotech com This page intentionally left blank...
Страница 48: ...Revision History Ndrive QL Hardware Manual 48 Appendix B www aerotech com This page intentionally left blank...
Страница 50: ...Index Ndrive QL Hardware Manual 50 Index www aerotech com This page intentionally left blank...