6.5. LED Indicators
The following LEDs are available on each Ndrive HP. Full Ndrive HP status is available
via the Nmotion SMC and its utilities.
These LED’s may also flash, to indicate that the internal MXH option is being re-
programmed internally, see Section 3.3.4.2 for more information on the LED-flashing
pattern which indicates the re-programming cycle is occurring.
Table 6-6.
LED Indicator Description
Label
Description
ACTV Reset
indicator
CLMT
Current is clamped at the value determined by the ThresholdClampIAmp
axis parameter
ENB
Axis is enabled
FLT
An axis fault has occurred, see Fault axis parameter
INPOS
Axis is in position
KRNL
Nmotion SMC controller is running
LMT+
Positive end of travel limit input active
LMT-
Negative end of travel limit input active
PERR
Position Error has exceeded the ThresholdPosError axis parameter
RMS
RMS motor current has exceeded the ThresholdAvgIAmp axis parameter