![Aerotech Ndrive HP 10 Скачать руководство пользователя страница 123](http://html1.mh-extra.com/html/aerotech/ndrive-hp-10/ndrive-hp-10_user-manual_2863043123.webp)
Troubleshooting
Ndrive HP 10/20/30 Manual
6-6
www.aerotech.com
Table 6-4.
Ndrive HP Power Board Jumper Selections
Jumpers
Positions
Function
In *
85 – 240 VAC Input Power Applied at TB102
JP1
Out
Less than 850 VAC Applied at TB102
In *
85 – 240 VAC Input Power Applied at TB102
JP2
Out
Less than 85 VAC Applied at TB102
1-2
Shunt Option not Present (std. On Ndrive HP 10, 20)
JP3
2-3
Shunt Option Present (std. On Ndrive HP 30)
1-2
115 VAC Shunt Option (165VDC Bus)
JP4
2-3*
230 VAC Shunt Option (330VDC Bus)
1-2*
Bus under-voltage detection enabled
JP5
2-3
Bus under-voltage detection disabled
1-2*
FireWire Bus power source
JP6
2-3
Disable FireWire Bus power source
* Factory Default
All jumpers are factory-configured and should not be
changed by the user.
Table 6-5.
Ndrive HP Power Board Fuse Information
Fuse
Description
Size
Ndrive 10: 5A S.B., 3AG
Ndrive 20: 10A S.B., 3AG
F1
Supply Main Fusing for L1 VAC Bus Input
Ndrive 30: 10A S.B., 3AG
F2
Shunt Option (-S)
2 A S.B. (5 mm)
F3
Control Power Fuse
.5 A S.B.
F4
Encoder 5 Volt Power
.9A Auto. Reset-able
F5
Optional 115/230 VAC Control Power Supply
Input
3 A S.B.
F1 and F2 are standard socketed fuses. F3 and F5 are soldered to the circuit board. See
Chapter 5: Troubleshooting for fuse replacement information.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com