![Aerotech MPS50SL Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/aerotech/mps50sl/mps50sl_hardware-manual_2863036012.webp)
Overview
MPS50SL Hardware Manual
1.1. Environmental Specifications
W A R N I N G : Do not expose this product to environments or conditions outside of the listed
specifications. Exceeding environmental or operating specifications can cause damage to the
equipment.
Table 1-2:
Environmental Specifications
Ambient
Temperature
Operating: 10° to 35° C (50° to 95° F)
The optimal operating temperature is 20° C ±2° C (68° F ±4° F). If at any time the
operating temperature deviates from 20° C, degradation in performance could occur.
Storage: 0° to 40° C (32° to 104° F) in original shipping packaging
Humidity
Operating: 20% to 60% RH
Storage: 10% to 70% RH, non-condensing in original packaging. The stage should be
packaged with desiccant if it is to be stored for an extended time.
Altitude
Operating: 0 m to 2,000 m (0 ft to 6,562 ft) above sea level
Contact Aerotech if your specific application involves use above 2,000 m or below sea
level.
Vibration
Use the system in a low vibration environment. Excessive floor or acoustical vibration
can affect system performance. Contact Aerotech for information regarding your spe-
cific application.
Protection
Rating
The MPS50SL is not suited for dusty or wet environments. This equates to an ingress
protection rating of IP00.
Use
Indoor use only
1.2. Accuracy and Temperature Effects
The accuracy specification of MPS50SL series stages is measured 25 mm above the table with the stage in
an unloaded condition. The stage is assumed to be fully supported by a mounting surface meeting or
exceeding the specification in
The accuracy of the screw is a key element in the overall positioning accuracy of the stage. A scale error can
be expected if temperature of the screw differs from 20° C (68° F). The greater the temperature difference,
the greater the error. The temperature of the screw depends on the speed and duty cycle of the stage. The
faster the movement and higher the duty cycle, the more the stage accuracy will be affected by heat. The
thermal expansion coefficient of the screw is 11.7 ppm/°C.
12
Chapter 1
www.aerotech.com
Содержание MPS50SL
Страница 1: ...Revision 1 01 00 MPS50SL Hardware Manual...
Страница 6: ...Table of Contents MPS50SL Hardware Manual 6 www aerotech com This page intentionally left blank...
Страница 8: ...Electrical Safety MPS50SL Hardware Manual 8 www aerotech com This page intentionally left blank...
Страница 10: ...Declaration of Conformity MPS50SL Hardware Manual 10 www aerotech com This page intentionally left blank...
Страница 44: ...Maintenance MPS50SL Hardware Manual 44 Chapter 4 www aerotech com This page intentionally left blank...
Страница 48: ...Revision History MPS50SL Hardware Manual 48 Appendix B www aerotech com This page intentionally left blank...