![Aerotech Automation1 iXC6e Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/aerotech/automation1-ixc6e/automation1-ixc6e_hardware-manual_2863025067.webp)
2.5.4. Digital Inputs
You can connect the digital inputs to current sourcing or current sinking devices but you must
connect all four inputs in the same configuration. Refer to
and
. The digital
inputs are not designed for high-voltage isolation applications. They should only be used with
ground-referenced circuits.
Table 2-39:
Digital Input Specifications
Input Voltage
Approximate Input Current
Turn On Time
Turn Off Time
+5 V to +24 V
6 mA
10 µs
43 µs
Table 2-40:
Digital Input Pins on the Auxiliary I/O Connector
Pin#
Description
In/Out/Bi
17
Digital Input 0 / CCW EOT Input
(1)
Input
18
Digital Input 1 / CW EOT Input
(1)
Input
24
Digital Input Common
Output
25
Digital Input 2 / Home Input
(1)
Input
26
Digital Input 3
Input
(1) Software configured option
Figure 2-32:
Digital Inputs Schematic (Aux I/O Connector)
iXC6e/XC6e Hardware Manual
2.5.4. Digital Inputs
www.aerotech.com
67
Содержание Automation1 iXC6e
Страница 1: ...Revision 1 04 Automation1 iXC6e and XC6e High Powered PWM Digital Drives HARDWARE MANUAL...
Страница 63: ...Figure 2 28 PSO Interface iXC6e XC6e Hardware Manual 2 5 2 Position Synchronized Output PSO www aerotech com 63...
Страница 86: ...Figure 3 2 Digital Outputs Schematic EB1 3 1 Digital Outputs EB1 iXC6e XC6e Hardware Manual 86 www aerotech com...
Страница 104: ...This page intentionally left blank Appendix B Revision History iXC6e XC6e Hardware Manual 104 www aerotech com...
Страница 112: ...Index iXC6e XC6e Hardware Manual This page intentionally left blank 112 www aerotech com...