Chapter 2: Installation and Configuration
The sections in this chapter include details on how to set up the electrical and safety components of
your system. Obey all safety warnings, including those in
Safety Procedures and Warnings
.
2.1. Input Power Connections
The drive has two AC input power connectors. One connector is for control power and the other
connector is for motor power. For a full list of electrical specifications, refer to
2.1.1. Control Supply Connector
DANGER: Shock and Fire Hazard
Electrical wiring must be designed and installed in accordance with local electrical
safety regulations to prevent the risk of fire and electrical shock.
The Control Supply input supplies power to the communications and logic circuitry of the drive . The
L
input is connected to an internal fuse. Refer to
for the internal fuse value and part
number. The
N
input is not connected to an internal fuse. An external fuse will be required if
N
is not
connected to Neutral.
The Control Supply contains an internal filter but you could be required to add an external filter for
CE compliance. Install the external filter module as close as possible to the drive. Use a Schaffner
FN2010-6-06, Corcom 10VW1, or similar filter.
Figure 2-1:
Control Supply Connections
Table 2-1:
Control Supply Wiring Pinout
Pin
Description
L
Line (L): 100-240 VAC Control Power Input
N
Neutral (N) or 100-240 VAC Control Power Input with external fuse
Protective Ground
Table 2-2:
Control Supply Wiring Specifications
Type
3-Pin Terminal Block
Aerotech Part Number
ECK02388
Manufacturer Part Number
(1)
Phoenix 1827635
Insulation Strip Length
7 mm (1/4 in)
Tightening Torque
0.5..0.6 N·m
One conductor stranded with ferrule and
plastic sleeve
14..22 AWG (0.25..2.5 mm
2
)
Two conductors with the same cross-
section, stranded, twin ferrule with plastic
sleeve
16..20 AWG (0.5..1.5 mm
2
)
(1) Refer to the manufacturer website for additional information.
iXC6e/XC6e Hardware Manual
Chapter 2: Installation and Configuration
www.aerotech.com
25
Содержание Automation1 iXC6e
Страница 1: ...Revision 1 04 Automation1 iXC6e and XC6e High Powered PWM Digital Drives HARDWARE MANUAL...
Страница 63: ...Figure 2 28 PSO Interface iXC6e XC6e Hardware Manual 2 5 2 Position Synchronized Output PSO www aerotech com 63...
Страница 86: ...Figure 3 2 Digital Outputs Schematic EB1 3 1 Digital Outputs EB1 iXC6e XC6e Hardware Manual 86 www aerotech com...
Страница 104: ...This page intentionally left blank Appendix B Revision History iXC6e XC6e Hardware Manual 104 www aerotech com...
Страница 112: ...Index iXC6e XC6e Hardware Manual This page intentionally left blank 112 www aerotech com...