3.1. Motor and Feedback Connectors
Stages equipped with standard motors and encoders come from the factory completely wired and
assembled.
IMPORTANT
: Refer to the other documentation accompanying your Aerotech
equipment. Call your Aerotech representative if there are any questions on system
configuration.
IMPORTANT
: If using standard Aerotech motors and cables, motor and encoder
connection adjustments are not required.
The protective ground connection of the ANT95LZ provides motor frame ground protection only.
Additional grounding and safety precautions are required for applications requiring access to the
stage while it is energized. The System Integrator or qualified installer is responsible for determining
and meeting all safety and compliance requirements necessary for the integration of this stage into
the final application.
DANGER: Electrical Shock Hazard!
l
The protective ground connection must be properly installed to minimize the
possibility of electric shock.
l
The stage controller must provide over-current and over-speed protection. Failure to
do so could cause electric shock or damage to the equipment.
3.1. Motor and Feedback Connectors
ANT95LZ Hardware Manual
32
www.aerotech.com
Содержание ANT95LZ Series
Страница 1: ...Revision 2 01 ANT95LZ Series Single Axis Z Direct Drive Nanopositioning Stage HARDWARE MANUAL...
Страница 6: ...This page intentionally left blank List of Tables ANT95LZ Hardware Manual 6 www aerotech com...
Страница 16: ...This page intentionally left blank Handling and Storage ANT95LZ Hardware Manual 16 www aerotech com...
Страница 22: ...Figure 2 2 ANT95LZ 025 Dimensions 2 1 Dimensions ANT95LZ Hardware Manual 22 www aerotech com...
Страница 40: ...This page intentionally left blank 3 5 Motor and Feedback Phasing ANT95LZ Hardware Manual 40 www aerotech com...
Страница 48: ...This page intentionally left blank Appendix B Revision History ANT95LZ Hardware Manual 48 www aerotech com...