Dedusting unit ecomax 100
V02.00 Page 26 of 40
Chapter 7 Maintenance and
7
Maintenance and control
When maintaining the machine, the following safety instructions must be observed
unconditionally - this will prevent life-threatening injuries to persons, machine
damage and other material damage as well as environmental damage.
Cleaning and maintenance work may only be carried out by authorised operating
personnel - the operating instructions must be followed exactly.
Repair work may only be carried out by authorised specialist personnel - the accident
prevention regulations must be observed.
All work on the electrical equipment of the machine may only be carried out by
licensed electricians.
Please also read chapter 2.3 'General safety instructions'!
NOTE
After completion of a maintenance or repair, make sure that all tools, cleaning
objects or other parts are removed from the machine.
NOTE
In your own interest, please note that any necessary repairs or
maintenance which goes beyond this technical documentation during the warranty
period can only be carried out by aeropur GmbH itself.
7.1
Checklist for maintenance work
Part
Check
Action
Interval
Air filters
Damage, soiling
Exchange
After differential pressure
exceeding or service life
exceeding (first filter stage
every 12 months, second
filter stage every 24
months)
Instrument housing
Damage,
corrosion,
soiling, water
formation
Maintenance, cleaning,
if necessary, determination of the cause of
water formation
Every 12 months
Fan, parts in
contact with air
Damage,
corrosion,
contamination
Maintenance, cleaning
Every 12 months
Air diffusers, interior,
filter cover,
exhaust air outlet
(blow-out
damper)
Damage, corrosion,
contamination, solid
deposits,
leakages
Cleaning
Every 12 months
Exchange
When required