Aeropro RP17411 Скачать руководство пользователя страница 6

adjusted. Without proper lubrication the tool will not work properly and parts will wear prematurely. 

z

 

Use the proper lubricant in the air line lubricator. The lubricator should be of low air flow or changing air flow 
type, and should be kept filled to the correct level. Use only recommended lubricants, specially made for 
pneumatic applications. Substitutes may harm the rubber compounds in the tools O-rings and other rubber 
parts. 

z

 

 

IMPORTANT!!! 

If a filter/regulator/lubricator is not installed on the air system, air operated tools should be lubricated at least once 
a day or after 2 hours work with 2 to 6 drops of oil, depending on the work environment, directly through the male 
fitting in the tool housing. 

 

 

 

 

 

 

Loading and operation 

 

 

)

W A R N I N G :

 

Ensure you read, understand and apply safety instructions before use.

 

1. Only use impact sockets which are specifically designed for use with impact wrench. 
2. Connect the wrench to the air hose . 
3. Place the socket over the subject nut and depress the trigger to operate the wrench.   
4. To change direction push the button at the top of the handle. Direction of .R. for reverse and “F” for forward 
5. The flow of air may be regulated by adjusting flow valve at the base of the handle. 
6. Ensure the air supply is clean and does not exceed 90psi while operating the wrench. Too high an air pressure 
and unclean air will shorten the product life due to excessive wear, and may be dangerous causing damage or 
personal injury. 
7. Make children away from the tools and workplaces. 
DO NOT use any additional force upon the wrench in order to remove a nut. 
DO NOT allow wrench to free run for an extended period of time as this will shorten its life. 
 

 Maintenance 

)

WA R N I NG :

 

Disconnect wrench from air supply before changing accessories, servicing or performing 

maintenance. Replace or repair damaged parts. 

Use genuine parts only. Non-authorised parts may be dangerous   

1. Lubricate the air wrench daily with a few drops of air tool oil dripped into the air inlet   
2. DO NOT use worn, or damaged sockets. 
3. Loss of power or erratic action may be due to the following: 

a)

 

Excessive drain on the air line. Moisture or restriction in the air pipe.   

b)

 

b

) Grit or gum deposits in the wrench may also reduce performance. If your model has an air strainer (located 

in the area of the air inlet), remove the strainer and clean it.   

4. When not in use, disconnect from air supply, clean wrench and store in a safe, dry, childproof location. 

※ 

Trouble Shooting 

 

The following form lists the common operating system with problem and solutions. Please read the form 

carefully and follow it. 

Содержание RP17411

Страница 1: ... safety rules Operating Instructions Maintenance Parts List 2013 3 8 Ratchet Wrench Model No RP17411 IMPORTANT Upon receipt of the product read and follow all safety rules operating instructions before first use it And retain this manual for future reference ...

Страница 2: ...tain correct balance and footing Ensure the floor is not slippery and wear non slip shoes 11 Keep children and non essential persons away from the working area 12 DO NOT use the wrench for a task it is not designed to perform 13 DO NOT use wrench if damaged or thought to be faulty 14 DO NOT use wrench unless you have been instructed in its use by a qualified person 15 DO NOT carry the wrench by th...

Страница 3: ...ing apply The use of the tool can expose the operator s hands to hazards including crushing impacts cuts and abrasions and heat Wear suitable gloves to protect hands Operators and maintenance personnel shall be physically able to handle the bulk weight and power of the tool Hold the tool correctly be ready to counteract normal or sudden movements and have both hands available Maintain a balanced b...

Страница 4: ...the exhaust so as to minimize disturbance of dust in a dust filled environment Where dust or fumes are created the priority shall be to control them at the point of emission All integral features or accessories for the collection extraction or suppression of airborne dust or fumes should be correctly used and maintained in accordance with the manufacturer s instructions Use respiratory protection ...

Страница 5: ...afety critical effect on performance Therefore requirements for length and diameter of the hose shall be specified Never carry an air tool by the hose Air supply 1 Ensure wrench air valve or trigger is in the off position before connecting to the air supply 2 You will require an air pressure of 90psi and an air flow according to specification 3 WARNING Ensure the air supply is clean and does not e...

Страница 6: ...alve at the base of the handle 6 Ensure the air supply is clean and does not exceed 90psi while operating the wrench Too high an air pressure and unclean air will shorten the product life due to excessive wear and may be dangerous causing damage or personal injury 7 Make children away from the tools and workplaces DO NOT use any additional force upon the wrench in order to remove a nut DO NOT allo...

Страница 7: ...t usually indicates insufficient grease in chamber Severe operating conditions may require more frequent lubrication Tool runs slowly Air flows slightly from exhaust Motor parts jammed with dirt particles Power regulator in closed position Air flow blocked by dirt Check air inlet filter for blockage Pour air tool lubricating oil into air inlet as per instructions Operate tool in short bursts quick...

Страница 8: ...r Plate 22 Steel ball 34 Rotor Blade 46 Sealing Coupler 11 Idler Gear Pin 23 Retainer ring 35 End plate 47 Rubber handle 12 Idler Gear Pin 24 Ratchet anvil 36 Bearing Note Please contact with us if customer need to know parts material If you need spare parts of this model pls feel free to contact us or the distributor where you bought this tool Tks EC DECLARATION OF CONFORMITY Business name of the...

Страница 9: ...Name address and identification number of the notified body TÜV Rheinland LGA Products GmbH Tillystrasse 2 90431 Nürnberg Germany 0197 and tested in accordance with below standards EN ISO 11148 6 2010 ...

Отзывы: