5. Maintenance 

Disconnect the tool from the compressor before adjusting, clearing jams, servicing &maintenance, relocating and during non operation. 

Regular lubrication, if your tool without using the in-liner automatic oilier, place 2 or 6 drops of pneumatic tool oil into the air inlet before 

each work day or after 2 hours of continuous use depending in the characteristic of workpiece or type of fasteners.   

      Air-operated tools must be inspected periodically, and worn or broken parts must be replaced to keep the tool operating safely and 

efficiently. Check and change all worn or damaged O-ring, Seals, etc. Tighten all the screws and caps to avoid personal injury. This 

should  be  done  by  an expert.    Make  regular inspection  for  free movement  of  trigger,  Spring  and safety  mechanism  to  assure safe 

system is complete and functional: no loose and missing parts, no building or stocking parts.    Keep magazine and nose of tool clean 

and free of any dirt lint or abrasive particles.    When temperatures are below freezing, tools should be kept warm by any convenient, 

safe method. 

                                                                                                                                                               

6. Troubleshooting 

(See Table 1) 

The following chart lists common operating system issues and solutions.please read it carefully and follow all instructions closely

DANGER! 

Potential hazard that could result in serious injury or loss of life.

 

If  any  of  the  following  symptoms  appear  while  the  tool  is  in  use,turn  it  off  and  disconnect  it  from  the  air  supply 

immediately. Failure to comply will lead to serious injury or loss of life. 

Disconnect the tool from the air supply before making any adjustments. 

Repairs must be performed by a qualified service technician only. 

SYMPTOM 

PROBLEM 

SOLUTIONS 

Air  leak  near  top  of 

tool or in trigger area   

1.O-ring in trigger valve are damage. 

2.Trigger valve head are damage. 

3.Trigger valve stem ,seal or O-ring are damaged. 

1.Check and replace O-ring. 

2.Check and replace. 

3.Check and replace trigger valve stem, seal or O-ring 

Air  leak  near  bottom 

of tool. 

1. Loose screws. 

2. Worn or damaged O-rings or bumper. 

1. Tighten screws. 

2. Check and replace O-rings or bumper. 

Air leak between body 

and cylinder cap. 

1. Loose screws. 

2. Worn or damaged O-rings or seals. 

1. Tighten screw. 

2. Check and replace O-rings or bumper. 

Blade  driving  fastener 

too deep. 

1. Worn bumper. 

2. Air pressure is too high. 

1. Replace bumper. 

2. Adjust the air pressure. 

Tool  does  not  operate 

well:  can  not  drive 

fastener 

or 

operate 

sluggishly.   

1. Inadequate air supply. 

2. Inadequate lubrication. 

3. Worn or damaged O-rings or seals. 

4. Exhaust port in cylinder head is blocked. 

1. Verify adequate air supply. 

2. Place 2 or 6 drops of oil into air inlet. 

3. Check and replace O-rings or seal. 

4. Replace damaged internal parts. 

Tool skips fasteners. 

1. Worn bumper or damaged spring. 

2. Dirt in front plate. 

3. Dirt or damage prevents fasteners from moving 

freely in magazine. 

4. 

Worn or dry O-ring on piston or lack of lubrication.

 

5. Cylinder cover seal leaking. 

1. Repalce bumper or pusher spring. 

2. Clean drive channel on front plate. 

3. Magazine needs to be cleaned. 

 

4. O-ring need to be replaced. And lubricate. 

5. Replace Sealing washer. 

Tool jams. 

1. Incorrect or damaged fasteners. 

2. Damaged or worn driver guide. 

3. Magazine or nose screw loose. 

4. Magazine is dirty.   

1. Change and use correct fastener. 

2. Check and replace the driver. 

3. Tighten the magazine. 

4. Clean the magazine. 

Table 1 

Содержание RHF9021

Страница 1: ... effective hearing protection is not worn Health defects resulting from vibration emission if the power tool is being used over longer period of time or not adequately managed and properly maintained Wear eye protection 2017 IMPORTANT Read all safety rules and operating Instructions carefully before first use it Keep this Manual for future reference TABLE OF CONTENTS QUICK START GUIDE TECHNICAL SP...

Страница 2: ... the tool PERSONAL SAFETY These precautions are intended for the personal safety of the user and others working with the user please take time to read and understand them DANGER Potential hazard that will result in serious injury or loss of life Keep children away from the work area Do not allow children to handle power tools Keep air hose away from heat oil and sharp edges Check air hose for wear...

Страница 3: ...n an elevated position that could allow the unit to fall or be tipped over Always replace a damaged gauge before operating the unit again CAUTION Potential hazard that may result in moderate injury or damage to equipment Always ensure that the tool has stopped before connecting to the air supply Do not wear watches rings bracelets or loose clothing when using any air tool Do not overload the tool ...

Страница 4: ...f feature a die cast aluminum housing and a comfortable handle for optimal control and comfort even during extended use It is well balanced for stability and ergonomically designed with a longer handle for ease of operation It also features a hardened driver blade for longer life and economical air consumption with low noise This air powered nailer is specifically designed for professional work Ai...

Страница 5: ...sting fastener Failure to comply could lead to serious injury or loss of life TYPES OF FASTENERS Please see the TECHNICAL SPECIFIACTIONS WARNING Potential hazard that could result in serious injury or loss of life The use of any other types of fasteners will cause the tool to jam Failure to comply could lead to serious injury or loss of life OPERATING INSTRUCTIONS 4 1 Preparing a tool for first ti...

Страница 6: ...l if the magazine is empty Any defective or improperly functioning fastener driving tool must immediately be disconnected from the compressed air supply and passed to a specialist for inspection In the event of longer breaks in work or at the end of the working shift disconnect the tool from the compressed air supply and it is recommended to empty the magazine The compressed air connectors of the ...

Страница 7: ...re making any adjustments Repairs must be performed by a qualified service technician only SYMPTOM PROBLEM SOLUTIONS Air leak near top of tool or in trigger area 1 O ring in trigger valve are damage 2 Trigger valve head are damage 3 Trigger valve stem seal or O ring are damaged 1 Check and replace O ring 2 Check and replace 3 Check and replace trigger valve stem seal or O ring Air leak near bottom...

Страница 8: ...25 Pin Compressed spring O ring 4 5 1 8 Mandril O ring 11 2x1 85 Valve rod Pin Bolt M5 16 Safety yoke compressed spring Safety yoke assembly Bolt M8x16 Handle sheath Washer End cap Spring washer Bolt M5 20 3 8 screwed connector Connector sheath Switch washer Urethane Ball Fixed piece Switch seat O ring 11 8x1 5 O ring 2 8x1 8 Switch rod Trigger Pin 3 30 Pusher rod Spring core Pin Scroll spring Pin...

Отзывы: