background image

0019-0015 Installation Instructions SunSpot 36-4313_4314 Rev IR     Page 5 of 9 

 

 

Wire Sizes 

  Reference: 

AC43.13-1B, Chapter 11, §4 and §5 

for appropriate wire sizing and fuse/breaker protection 

 

Removal 

  Prepare the aircraft for maintenance: Make sure all switches are in the OFF/NORMAL position, attach 

maintenance warning tags, pull landing/taxi light circuit breakers. 

  Reference airframe 

manufacturer’s current maintenance manual to remove any light covers to gain 

access to lamp assembly(s) and bracket(s). 

  Disconnect connection to positive aircraft power. 
  Disconnect ground from aircraft power. 
  Remove existing lamp(s) from brackets, mark and retain hardware. 
  Record weight of removed lamps. 

 

Installation 

 

Reference airframe manufacturer’s current maintenance manual and install LED light(s) in brackets 
using retained hardware. 

  Install suitable aircraft approved connecters to wires coming from landing light assemblies and wires 

routed from switch using appropriate wiring diagram to the number of lights shown on pages 7-9. 

Note

 

that the non pulsing version only has screw terminals for #6 ring terminals and does not support the 
pulse function. The screw terminals are not polarized, so the power and ground can be connected to 
them in either order. The positive wire for powering the pulse mode is connected to the yellow wire.   
Follow the wiring diagrams for connecting the blue and green synchronization wires for two and four 
light installations. 

  If necessary, install an appropriate aircraft approved switch and circuit breaker of correct rating for the 

lights installed for the pulse function. Original landing light switch/switches may be used. 

  Placard switches appropriately. 
  Power up aircraft and verify proper operation of LED light(s), in both pulsing and steady functions (as 

appropriate to the installation) 

  Using the appropriate aircraft maintenance manual, verify that the light angle has not changed, and is 

oriented & aimed in accordance with manufacturer’s instructions. 

  Perform EMI test to verify there is no interference caused by light installation. 
  Reinstall any light covers removed to gain access to lamp assemblies and brackets. 
  Enter appropriate logbook entry detailing work, and if necessary fill out and submit appropriate form 

337 for work accomplished. 

  Perform an operational check of the landing/taxi light(s) in accordance with 

14CFR, §91.407 (b) (c)

 to 

determine that the installed landing/taxi light(s) provide enough light for night operations in accordance 
with 

14CFR, §23.1383

 

Weight & balance change from standard position light assemblies to LED landing light assemblies is 
considered negligible.

 

 

Troubleshooting 

  Check for bus voltage at power input wire to the light, reestablish power if inadequate power is found.  

Check for excessive resistance at light ground and repair if necessary. Remove and bench check light if 
wiring is verified good. 

 

 

Содержание Sunspot 36 4313-H

Страница 1: ...istory follows on page 2 This document contains proprietary information of AeroLEDs Neither receipt nor possession thereof confer any right to reproduce or use or disclose in whole or in part any such information without written permission from AeroLEDs Approval Name Intent Author Robert Prew Installation and Operation Instructions for the Sunspot 36 4313 4314 series lights 01 1030 4313 4314 Check...

Страница 2: ...lations 3 Equipment Limitations 3 Airworthiness Limitations 4 Instructions for Continued Airworthiness 4 Installation Procedures 4 Wire Sizes 5 Removal 5 Installation 5 Troubleshooting 5 Wiring Diagrams 6 Wiring Diagram for Single Sunspot with Pulse 6 Wiring Diagram for Single Sunspot Without Pulse 6 Wiring Diagram for Dual SunSpots with Wig Wag 7 Wiring Diagram for Four LED SunSpots with Wig Wag ...

Страница 3: ...on mode Operational Voltage 14 Volt DC Input Current 6 5 Amps Peak Limitations and Installations Equipment Limitations Mount in approved PAR36 bulb holder with circuit breaker or fuse appropriate for rated current For retrofit installation existing circuit breaker or fuse can typically be used The procedures contained herein are not intended to conflict with the procedures set forth by aircraft an...

Страница 4: ... be sent to manufacturer for repair replacement if defective Installation Procedures The installation procedure described in the following text is for a single light installation and multiple light installations The pulsing function of the H model landing and or taxi light s is a self contained feature and does not require the use of an externally mounted pulse light controller Wiring diagrams are...

Страница 5: ...the wiring diagrams for connecting the blue and green synchronization wires for two and four light installations If necessary install an appropriate aircraft approved switch and circuit breaker of correct rating for the lights installed for the pulse function Original landing light switch switches may be used Placard switches appropriately Power up aircraft and verify proper operation of LED light...

Страница 6: ...v IR Page 6 of 9 Wiring Diagrams Wiring Diagram for Single Sunspot with Pulse Photo 2 1 Fuse breaker should be rated for wire size per AC43 13 1B Wiring Diagram for Single Sunspot Without Pulse Photo 2 2 Fuse breaker should be rated for wire size per AC43 13 1B ...

Страница 7: ...0019 0015 Installation Instructions SunSpot 36 4313_4314 Rev IR Page 7 of 9 Wiring Diagram for Dual SunSpots with Wig Wag Photo 2 3 Fuse breaker should be rated for wire size per AC43 13 1B ...

Страница 8: ...8 of 9 Wiring Diagram for Four LED SunSpots with Wig Wag Photo 2 4 Optional Diode D1 If all four lights are desired to turn on when landing place a Diode rated for 15 Amps at 14V between the landing and taxi wires Fuse breaker should be rated for wire size per AC43 13 1B ...

Страница 9: ... 0015 Installation Instructions SunSpot 36 4313_4314 Rev IR Page 9 of 9 DO 160E Section Compliance Level 4 F2 5 S2 6 B 7 A 8 U 9 H 10 S 11 F 12 S 13 F 14 T 15 A 16 Z 17 A 18 Z 19 ZC 20 RR 21 H 22 A3E3 24 C ...

Отзывы: