mode. You can deactivate Smart Start in the menu item
"Programming". When the Smart Start is deactivated, the
electric radiator starts heating when the set start time is
reached.
Learning phase: In order to reach the target temperature ex-
actly at the start time of each programmed time window,
your FlexiSmart carries out a learning phase in the first seven
days. During this time, heating is always started 15 minutes
before the set start time (in every single time window).
As a result, the FlexiSmart controller learns how fast or slow
heating takes place in the room and adjusts the „smart start
time“ of heating. After the learning phase, the FlexiSmart
controller decides when to start heating up. Your rooms will
be heated up as effectively as possible.
Status-Display
The first menu, you will see after
switching your AeroFlow® heater. It
shows the current time on the top left (for setting see page
14). The large display next to the thermometer icon shows
the current room temperature. The small temperature in
the lower right corner shows the target temperature.
Depending on the program setting, the following icons are
visible:
= The AeroFlow® heater is in program mode (see page 11).
=Manual mode (program mode Off ). The target tem-
perature will be controlled via the arrow buttons.
= The heater is heating. As soon as the heating ele-
ments do switch off, this symbol disappears.
= Open window detected, the AeroFlow® heater is tem-
porarily switched off.
= Holiday Mode: The digit below the icon indicates the
number of remaining holidays (see page 12).
= Keylock/Childlock ON (to enable/disable press both
arrow buttons simultaneously for min. 5 sec.).
NOTES:
If the clock symbol (program mode) is not displayed, lower
or raise the target temperature by using the arrow buttons.
The AeroFlow® heater will always hold this temperature.
In case the program mode is enabled (the clock symbol is
displayed), the target temperature can also be lowered and
raised with the arrow buttons. The manually set target tem-
perature overrides the program mode until the next preset
time frame. The AeroFlow® heater returns to programming
mode after then.
To turn the heater off, keep the OK button pressed for min.
5 seconds. The "sleeping mode" will be displayed.
Temperature-Overview
The display view changes after 5
seconds without pressing a button.
The current temperature is dis-
played on top and the target tem-
perature at bottom.
In this menu you will change (pro-
gramming mode) or overview the
heating times. You don't see this
menu item?
Enable the programming mode in
the main settings by switching "Pro-
gramming" to "ON".
Select this menu if you want to
view the heating plan. You can
not make changes in this menu
item.
Select the day of the week for
which you want to see the
heating plan.
See the heating plan on the
choosen day. Press OK to exit
the menu item display.
www.zatopte.si
4
12:34
21
.7
15.5°C
°C
15
.5
21.7°C
°C
OK
Programs
See
Select
da
y
Thursday
Start End Temp
00:00 08:00 11,0°C
08:00 16:00 19,0°C
16:00 00:00 11,0°C
--:-- --:-- -- °C
--:-- --:-- -- °C
--:-- --:-- -- °C