MAINTENANCE MANUAL
IFR 4000
2-2-3
Page 41
Aug 1/04
(19) SWR Meter
TEST EQUIPMENT:
50
Ω
Load
75
Ω
Load
100
Ω
Load
150
Ω
Load
VERIFICATION FAILURE:
If any step in this procedure fails or is out of tolerance,
this indicates a failure in the Test Set. Refer to
Troubleshooting for corrective action.
STEP PROCEDURE
1. Press the SETUP Key to display the Setup Menu.
2. Set the GEN FREQ Field to
VAR
.
3. Connect the 50
Ω
Load to the SWR Connector.
4. Set the FREQ Field as follows and verify readings on the Test Set:
FREQ READINGS
75 1.000
(
±
0.2 +
±
20% of reading)
137 1.000
(
±
0.2 +
±
20% of reading)
225 1.000
(
±
0.2 +
±
20% of reading)
312 1.000
(
±
0.2 +
±
20% of reading)
400 1.000
(
±
0.2 +
±
20% of reading)
5. Disconnect the 50
Ω
Load from the SWR Connector and connect the 75
Ω
Load
to the SWR Connector.
6. Set the FREQ Field as follows and verify readings on the Test Set:
FREQ READINGS
75 1.500
(
±
0.2 +
±
20% of reading)
137 1.500
(
±
0.2 +
±
20% of reading)
225 1.500
(
±
0.2 +
±
20% of reading)
312 1.500
(
±
0.2 +
±
20% of reading)
400 1.500
(
±
0.2 +
±
20% of reading)
7. Disconnect the 75
Ω
Load from the SWR Connector and connect the 100
Ω
Load
to the SWR Connector.
Содержание IFR 4000
Страница 1: ...NAV COMM Test Set Maintenance Manual 1002 5600 4P0 IFR 4000...
Страница 3: ...MAINTENANCE MANUAL IFR 4000 FOR QUALIFIED SERVICE PERSONNEL ONLY...
Страница 4: ...MAINTENANCE MANUAL IFR 4000 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 6: ...MAINTENANCE MANUAL IFR 4000 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 10: ...MAINTENANCE MANUAL IFR 4000 TABLE OF CONTENTS Page 2 Aug 1 04 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 12: ...MAINTENANCE MANUAL IFR 4000 INTRODUCTION Page 2 Aug 1 04 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 16: ...MAINTENANCE MANUAL IFR 4000 2 LIST OF ILLUSTRATIONS TABLES Page 2 Aug 1 04 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 32: ...MAINTENANCE MANUAL IFR 4000 2 2 1 Page 14 Aug 1 04 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 34: ...MAINTENANCE MANUAL IFR 4000 2 2 1 Page 16 Aug 1 04 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 42: ...MAINTENANCE MANUAL IFR 4000 2 2 2 Page 8 Aug 1 04 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 108: ...MAINTENANCE MANUAL IFR 4000 2 2 4 Page 2 Aug 1 04 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 143: ...MAINTENANCE MANUAL IFR 4000 2 2 4 Page 37 Aug 1 04 056M 09 Figure 12 LCD Assy 7110 5600 000 A 56A1A2A4...
Страница 160: ...MAINTENANCE MANUAL IFR 4000 2 2 4 Page 54 Aug 1 04 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 166: ...MAINTENANCE MANUAL IFR 4000 2 3 1 Page 6 Aug 1 04 STEP PROCEDURE 4 Remove the Fuse...
Страница 168: ...MAINTENANCE MANUAL IFR 4000 2 3 1 Page 8 Aug 1 04 STEP PROCEDURE 3 Remove four screws 4 Open the Case Assy...
Страница 174: ...MAINTENANCE MANUAL IFR 4000 2 3 1 Page 14 Aug 1 04 STEP PROCEDURE 3 Remove 11 screws 4 Remove Multi Function PCB Assy...
Страница 186: ...MAINTENANCE MANUAL IFR 4000 APPENDIX B Page 2 Aug 1 04 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 188: ...MAINTENANCE MANUAL IFR 4000 APPENDIX C Page 2 Aug 1 04 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 200: ...MAINTENANCE MANUAL IFR 4000 APPENDIX D Page 12 Aug 1 04 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 206: ...MAINTENANCE MANUAL IFR 4000 APPENDIX E Page 6 Aug 1 04 THIS PAGE INTENTIONALLY LEFT BLANK...