background image

MOS - UNO - IP 

MANUAL

STEENWEG 148C - 9810 NAZARETH - BELGIUM  -  T +32 (0)9 396 76 40 - [email protected] 

When there is no GPI active, the Mika arm LED will turn white. By default it is set to fade slowly. To 
deactivate fading put the fade speed fully to the left.

IP settings

Here the IP address with the corresponding subnet mask can be set. The MAC address is unique for 
each device and can not be changed. The firmware shows the currently running firmware version of 
the device.

Save settings

  

After setting all system parameters these settings have to be saved. To save all settings click save 
and reboot. The MOS-UNO-IP will store all settings and reboot. After approximately 5 seconds the 
webpage can be reloaded.

Standby settings

Содержание MOS - UNO - IP

Страница 1: ... 0 9 396 76 40 INFO AEROAUDIO EU Status indication white or red Mika microphone input Microphone output Ethernet network connection SUB D 9 GPI input Power supply 12 till 24 volt DC polarity is not important Power consumption at 12 volts 100mA at 24 volts 70mA ...

Страница 2: ... IP and wait for 5 seconds during boot the status LED will blink fast in red After the reset boot the satus LED will turn white and facory default settings are restored The MOS UNO IP can be reached at 192 168 0 101 again GPI schematic Pin Function Signal 1 GPI voltage control 5 till 15 volt DC 2 GPI close contact to GND Contact to pin 7 8 of 9 3 4 5 RESET settings Contact to pin 7 8 of 9 6 GND GP...

Страница 3: ...er the IP address in your browser and the MOS UNO IP will display the following settings page Mode Discription selected Current settings SUB D GPI only Triggers only on SUB D GPI Connect to device Connects to an Axia node or QOR Listen to server Triggers on TCP commands Connect to device connects directly to an Axia node or QOR Listen to server listens to TCP commands send from an external TCP ser...

Страница 4: ...ts on the QOR to trigger the MOS UNO IP select Node as device On using the Axia livewire software driver the Node needs to be selected as device DHD global logics Listens to DHD global logics Enter the DHD Toolbox project ID in the field of TCP command 1 Enter the used global logic number 1 200 in the field of TCP command 2 See GPI settings for details The webpage of the MOS UNO IP shows the conne...

Страница 5: ... to fader 3 the MOS UNO IP will follow the change On first installation or reboot of the MOS UNO IP a show profile has to be loaded to let the MOS UNO IP know the corresponding fader channel GPIO Pin and TCP off settings are not used when the QOR has been selected On choosing listen to server the MOS UNO IP will only listen on TCP port93 to commands directly send to the IP address of the MOS UNO I...

Страница 6: ...ngs Here the IP address with the corresponding subnet mask can be set The MAC address is unique for each device and can not be changed The firmware shows the currently running firmware version of the device Save settings After setting all system parameters these settings have to be saved To save all settings click save and reboot The MOS UNO IP will store all settings and reboot After approximatel...

Страница 7: ...MOS UNO IP MANUAL Dimensions STEENWEG 148C 9810 NAZARETH BELGIUM T 32 0 9 396 76 40 INFO AEROAUDIO EU Dimensions 140 81 9 41 6 mm Weight 0 35 Kg ...

Страница 8: ...ower supply Do not use the unit if the power cord is frayed or broken Turn off and disconnect the devices from the power supply before making any connections Do not use the unit near heaters heating vents radiators or other devices that produce heat Do not use the unit on a surface or in an environment that may interfere with the normal flow of air around the unit If the unit is used in an extreme...

Отзывы: